Panel de vision de salle blanche résistant au feu
- Specialist Fire-Glass Core
- Flush Protective Outer Panes
- Concealed Steel Subframe
- Assembly-Based Configuration
Introduction de produit
The fire-resistant vision panel is built as a complete glazing-and-frame assembly rather than by substituting a pane into a standard cleanroom window. A specialist fire-glass layer is protected by toughened outer panes, retained within a steel or stainless-steel subframe and finished flush to the cleanroom surfaces. Glass type, edge cover, seal materials, opening size and wall construction are selected together so the supplied configuration can match the documented fire strategy without sacrificing cleanability.
Key Features
A concealed metal subframe supports the heavier glazing stack and maintains defined edge cover.
Screen-printed borders hide fire-compatible seals and mechanical retention from the room face.
Mullions and alternative glazing makeups allow the assembly to address different opening sizes and insulation needs.
Préoccupations du client produit
Fire performance depends on the complete wall, frame, seal and glazing construction, while the cleanroom-facing surfaces must remain flush and accessible for cleaning.
Les applications typiques
Paramètres techniques
The ranges below describe common cleanroom fire-vision constructions; any declared fire performance applies only to the corresponding documented assembly.
| Matériaux de base | Specialist clear fire-resistant glass protected by toughened safety-glass outer panes |
|---|---|
| Panneau épaisseur | 30–70 mm glazing stack; typically 75–150 mm overall frame depth |
| Largeur effective | 300–1200 mm clear viewing width for common single-light assemblies |
| Longueur maximale | 2400 mm overall window height, subject to the selected documented construction |
| Acier face épaisseur | 1.2–2.0 mm stainless or galvanized-steel subframe and liners |
| Densité Core | Configuration-dependent multi-layer glass; typically 2500–3000 kg/m³ |
| Conductivité thermique | Approximately 0.3–1.0 W/(m·K), depending on the selected fire-glass composition |
| surface finie | Flush clear toughened outer glass with bonded ceramic-frit border and brushed stainless trim |
| Type joint | Mechanically retained fire-glass assembly with fire-compatible seals and concealed subframe |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation |
Options disponibles
Planning a Fire-Resistant Cleanroom Vision Panel specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien