Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Controle de sala limpa e sistemas de monitoramento ambiental

Sistema de Controle de Grupo FFU

A networked controller that supervises large banks of fan filter units, distributes speed setpoints and identifies individual FFU faults from one operator panel.
  • Individual FFU Addressing
  • Grouped Speed Commands
  • Live Motor Feedback
  • Fault Location by Unit
Solicite um orçamento. Browse produtos

Introdução do produto

The FFU group control system connects individually addressed EC fan filter units through dedicated communication branches and industrial gateways. Operators can start, stop or change speed by room, zone or selected unit while receiving actual speed, current and fault status from each fan. Scheduled occupied and setback modes reduce unnecessary fan energy outside production periods. Branch segmentation keeps troubleshooting practical in large ceilings because a communication issue can be isolated without losing visibility of every cleanroom zone.

Características-chave

Addressable communication maps each fan filter unit to its physical ceiling location.

Zone commands change multiple EC fan speed setpoints without editing every unit separately.

Returned speed, current and alarm states reveal stalled or disconnected FFUs quickly.

Segmented gateways support orderly expansion across multiple cleanroom ceiling grids.

Preocupações do produto do cliente

A large FFU ceiling needs centralized control without making a single branch fault difficult to diagnose or service.

Technicians cannot identify which fan in a dense ceiling grid has failed.Addressed status feedback links each alarm to a room coordinate and FFU number.
Manual speed adjustment creates inconsistent airflow across adjacent zones.Group setpoints apply a coordinated command to every selected FFU branch.
Full-speed operation during idle hours wastes fan energy.Scheduled occupied and setback commands reduce speed when process demand is lower.
One communication fault can obscure a large number of ceiling units.Multiple isolated branches and gateways limit the affected section and preserve the remaining network.

Aplicações típicas

Semiconductor cleanroom ceilingsPharmaceutical filling suitesElectronics assembly cleanroomsModular cleanroom installations

Parâmetros técnicos

Typical construction for an FFU group control cabinet serving networked EC fan filter units is listed below.

Material principalPowder-coated steel cabinet with FR-4 control boards, isolated RS-485 interfaces and copper terminals
Painel de espessura180-350 mm cabinet depth
Largura efetiva500-1000 mm enclosure width
Comprimento máximoUp to 1800 mm enclosure height
Aço enfrentando espessura1.2-1.8 mm powder-coated steel panels
Densidade Core7800-8050 kg/m³ for steel enclosure components
Condutividade térmica45-60 W/(m·K) for steel structural parts
Superfície acabadoLight-gray textured powder coat with blue HMI bezel and labeled branch indicators
Tipo conjuntoDIN-rail modular cabinet with segregated power and multi-branch Modbus terminal sections
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Modbus RTU or TCP gatewaysTouchscreen ceiling mapOccupied and setback schedulesRedundant communication branches

Planning a FFU Group Control System specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato