Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Control de salas limpias y sistemas de monitoreo ambiental

Sistema de control de grupo FFU

A networked controller that supervises large banks of fan filter units, distributes speed setpoints and identifies individual FFU faults from one operator panel.
  • Individual FFU Addressing
  • Grouped Speed Commands
  • Live Motor Feedback
  • Fault Location by Unit
Solicite un presupuesto. Browse productos

Introducción del producto

The FFU group control system connects individually addressed EC fan filter units through dedicated communication branches and industrial gateways. Operators can start, stop or change speed by room, zone or selected unit while receiving actual speed, current and fault status from each fan. Scheduled occupied and setback modes reduce unnecessary fan energy outside production periods. Branch segmentation keeps troubleshooting practical in large ceilings because a communication issue can be isolated without losing visibility of every cleanroom zone.

Características clave

Addressable communication maps each fan filter unit to its physical ceiling location.

Zone commands change multiple EC fan speed setpoints without editing every unit separately.

Returned speed, current and alarm states reveal stalled or disconnected FFUs quickly.

Segmented gateways support orderly expansion across multiple cleanroom ceiling grids.

Preocupaciones del producto del cliente

A large FFU ceiling needs centralized control without making a single branch fault difficult to diagnose or service.

Technicians cannot identify which fan in a dense ceiling grid has failed.Addressed status feedback links each alarm to a room coordinate and FFU number.
Manual speed adjustment creates inconsistent airflow across adjacent zones.Group setpoints apply a coordinated command to every selected FFU branch.
Full-speed operation during idle hours wastes fan energy.Scheduled occupied and setback commands reduce speed when process demand is lower.
One communication fault can obscure a large number of ceiling units.Multiple isolated branches and gateways limit the affected section and preserve the remaining network.

Aplicaciones típicas

Semiconductores Cleanroom TechoPharmaceutical filling suitesElectronics assembly cleanroomsModular cleanroom installations

Parámetros técnicos

Typical construction for an FFU group control cabinet serving networked EC fan filter units is listed below.

Materiales CorePowder-coated steel cabinet with FR-4 control boards, isolated RS-485 interfaces and copper terminals
Panel de espesor180-350 mm cabinet depth
Ancho efectivo500-1000 mm enclosure width
Longitud máximaUp to 1800 mm enclosure height
Acero frente a espesor1.2-1.8 mm powder-coated steel panels
Densidad Core7800-8050 kg/m³ for steel enclosure components
Conductividad térmica45-60 W/(m·K) for steel structural parts
Superficie acabadaLight-gray textured powder coat with blue HMI bezel and labeled branch indicators
Tipo conjuntoDIN-rail modular cabinet with segregated power and multi-branch Modbus terminal sections
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Modbus RTU or TCP gatewaysTouchscreen ceiling mapOccupied and setback schedulesRedundant communication branches