Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda Kontrolü ve Çevre İzleme Sistemleri

FFU Grup Kontrol Sistemi

A networked controller that supervises large banks of fan filter units, distributes speed setpoints and identifies individual FFU faults from one operator panel.
  • Individual FFU Addressing
  • Grouped Speed Commands
  • Live Motor Feedback
  • Fault Location by Unit
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The FFU group control system connects individually addressed EC fan filter units through dedicated communication branches and industrial gateways. Operators can start, stop or change speed by room, zone or selected unit while receiving actual speed, current and fault status from each fan. Scheduled occupied and setback modes reduce unnecessary fan energy outside production periods. Branch segmentation keeps troubleshooting practical in large ceilings because a communication issue can be isolated without losing visibility of every cleanroom zone.

Ana Özellikler

Addressable communication maps each fan filter unit to its physical ceiling location.

Zone commands change multiple EC fan speed setpoints without editing every unit separately.

Returned speed, current and alarm states reveal stalled or disconnected FFUs quickly.

Segmented gateways support orderly expansion across multiple cleanroom ceiling grids.

Müşteri Ürün Sorunları

A large FFU ceiling needs centralized control without making a single branch fault difficult to diagnose or service.

Technicians cannot identify which fan in a dense ceiling grid has failed.Addressed status feedback links each alarm to a room coordinate and FFU number.
Manual speed adjustment creates inconsistent airflow across adjacent zones.Group setpoints apply a coordinated command to every selected FFU branch.
Full-speed operation during idle hours wastes fan energy.Scheduled occupied and setback commands reduce speed when process demand is lower.
One communication fault can obscure a large number of ceiling units.Multiple isolated branches and gateways limit the affected section and preserve the remaining network.

Tipik uygulamalar

Semiconductor cleanroom ceilingsPharmaceutical filling suitesElectronics assembly cleanroomsModular cleanroom installations

Teknik parametreler

Typical construction for an FFU group control cabinet serving networked EC fan filter units is listed below.

Temel malzemelerPowder-coated steel cabinet with FR-4 control boards, isolated RS-485 interfaces and copper terminals
Panel kalınlığı180-350 mm cabinet depth
Effective Width (Etkili Genişlik)500-1000 mm enclosure width
Maksimum uzunlukUp to 1800 mm enclosure height
Çelik yüz yüze kalınlığı1.2-1.8 mm powder-coated steel panels
Core Density (Çekirdek Yoğunluğu)7800-8050 kg/m³ for steel enclosure components
Termal İletkenlik45-60 W/(m·K) for steel structural parts
Yüzey bitirmeLight-gray textured powder coat with blue HMI bezel and labeled branch indicators
Ortak tipDIN-rail modular cabinet with segregated power and multi-branch Modbus terminal sections
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Modbus RTU or TCP gatewaysTouchscreen ceiling mapOccupied and setback schedulesRedundant communication branches