Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Instrumentos de ensaio e validação de sala limpa

Teste de vazamento de dutos

A portable positive/negative duct leakage tester with variable blower, calibrated flow measurement and automatic pressure control for HVAC commissioning.
  • Controlled positive and negative duct pressurization.
  • Calibrated leakage-flow measurement.
  • Portable integrated field test system.
Solicite um orçamento. Browse produtos

Introdução do produto

This self-contained tester connects to an isolated duct section, raises or lowers it to a defined pressure and measures the airflow required to hold that condition. A variable-speed blower, calibrated inlet and dual pressure channels allow the controller to calculate leakage rate during positive or negative tests. The wheeled enclosure and flexible test hose support field commissioning across large installations.

Características-chave

Reversible blower supports positive and negative duct tests.

Closed-loop control maintains the selected test pressure.

Calibrated inlet measurement quantifies stabilizing leakage airflow.

Dual pressure channels monitor duct pressure and flow element.

Guided controller calculates leakage rate and test duration.

Wheeled field enclosure organizes hose, cables and adapters.

Preocupações do produto do cliente

Duct leakage must be quantified at a stable specified pressure even though the system response changes with seal quality, section size and test direction.

Test pressure drifts as leakage changes during the run.Closed-loop blower control continuously adjusts flow to maintain the selected pressure.
One-direction equipment cannot assess both supply and extract ductwork.A reversible flow arrangement supports positive and negative pressure tests.
Leakage calculations vary when technicians use separate instruments.Integrated pressure and calibrated-flow channels calculate leakage within one guided workflow.
Large test equipment is difficult to move through an active site.A compact wheeled enclosure and stored flexible hose simplify relocation between duct sections.

Aplicações típicas

Cleanroom supply-duct leakage testingExhaust and return duct commissioningNew ductwork quality verificationPost-repair airtightness checksHVAC leakage-class documentation

Parâmetros técnicos

Representative portable leakage-tester construction is shown below; blower capacity, calibrated flow range and hose size can be selected for the duct sections under test.

Material principalVariable-speed centrifugal blower, calibrated flow nozzle, pressure sensors and powder-coated steel enclosure
Painel de espessuraTypically 1.0-2.0 mm for the steel cabinet panels
Largura efetivaApproximately 450-650 mm across the mobile enclosure
Comprimento máximoApproximately 700-1000 mm including wheeled cabinet and stored hose
Aço enfrentando espessuraTypically 1.0-2.0 mm for powder-coated steel enclosure panels
Densidade CoreApproximately 7850 kg/m³ for structural steel components
Condutividade térmicaApproximately 45-55 W/(m·K) for structural steel components
Superfície acabadoSafety-yellow powder-coated cabinet with graphite controls, black hose and stainless fittings
Tipo conjuntoCam-lock flexible duct connection with sealed calibrated inlet and barbed pressure taps
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Low- or high-flow configurationPositive/negative test modeMultiple calibrated flow nozzlesFlexible connection hose sizesReport download and printingCobertura de transporte de proteção

Planning a Duct Leakage Tester specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato