Pembekal Satu Henti Anda untuk Peralatan Bilik Bersih dan Kemudahan AseptikSokongan Projek Antarabangsa
Open mobile navigationClose mobile navigation
Instrumen Ujian dan Pengesahan Bilik Bersih

Penguji Kebocoran Saluran

A portable positive/negative duct leakage tester with variable blower, calibrated flow measurement and automatic pressure control for HVAC commissioning.
  • Controlled positive and negative duct pressurization.
  • Calibrated leakage-flow measurement.
  • Portable integrated field test system.
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

This self-contained tester connects to an isolated duct section, raises or lowers it to a defined pressure and measures the airflow required to hold that condition. A variable-speed blower, calibrated inlet and dual pressure channels allow the controller to calculate leakage rate during positive or negative tests. The wheeled enclosure and flexible test hose support field commissioning across large installations.

Ciri-ciri Utama

Reversible blower supports positive and negative duct tests.

Closed-loop control maintains the selected test pressure.

Calibrated inlet measurement quantifies stabilizing leakage airflow.

Dual pressure channels monitor duct pressure and flow element.

Guided controller calculates leakage rate and test duration.

Wheeled field enclosure organizes hose, cables and adapters.

Kebimbangan Produk Pelanggan

Duct leakage must be quantified at a stable specified pressure even though the system response changes with seal quality, section size and test direction.

Test pressure drifts as leakage changes during the run.Closed-loop blower control continuously adjusts flow to maintain the selected pressure.
One-direction equipment cannot assess both supply and extract ductwork.A reversible flow arrangement supports positive and negative pressure tests.
Leakage calculations vary when technicians use separate instruments.Integrated pressure and calibrated-flow channels calculate leakage within one guided workflow.
Large test equipment is difficult to move through an active site.A compact wheeled enclosure and stored flexible hose simplify relocation between duct sections.

Permohonan yang biasa

Cleanroom supply-duct leakage testingExhaust and return duct commissioningNew ductwork quality verificationPost-repair airtightness checksHVAC leakage-class documentation

Parameter teknikal

Representative portable leakage-tester construction is shown below; blower capacity, calibrated flow range and hose size can be selected for the duct sections under test.

Bahan TerasVariable-speed centrifugal blower, calibrated flow nozzle, pressure sensors and powder-coated steel enclosure
Ketebalan PanelTypically 1.0-2.0 mm for the steel cabinet panels
Lebar berkesanApproximately 450-650 mm across the mobile enclosure
Panjang maksimumApproximately 700-1000 mm including wheeled cabinet and stored hose
Keluli Menghadapi KetebalanTypically 1.0-2.0 mm for powder-coated steel enclosure panels
Ketumpatan terasApproximately 7850 kg/m³ for structural steel components
Kekonduksian TermaApproximately 45-55 W/(m·K) for structural steel components
Kemasan permukaanSafety-yellow powder-coated cabinet with graphite controls, black hose and stainless fittings
Jenis BersatuCam-lock flexible duct connection with sealed calibrated inlet and barbed pressure taps
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Low- or high-flow configurationPositive/negative test modeMultiple calibrated flow nozzlesFlexible connection hose sizesReport download and printingPerlindungan pengangkutan perlindungan

Planning a Duct Leakage Tester specification?

Hantarkan kepada kami dimensi anda, syarat pemasangan, sasaran prestasi dan kemasan permukaan yang diperlukan.

Berbincang dengan pasukan kami
Email Kami WhatsApp WeChat

Laman Utama

Produk

Berita

Tentang Kami

Hubungi Kami