Duct Leakage Tester

A portable positive/negative duct leakage tester with variable blower, calibrated flow measurement and automatic pressure control for HVAC commissioning.
  • Controlled positive and negative duct pressurization.
  • Calibrated leakage-flow measurement.
  • Portable integrated field test system.

Produkteinführung

This self-contained tester connects to an isolated duct section, raises or lowers it to a defined pressure and measures the airflow required to hold that condition. A variable-speed blower, calibrated inlet and dual pressure channels allow the controller to calculate leakage rate during positive or negative tests. The wheeled enclosure and flexible test hose support field commissioning across large installations.

Key Features

Reversible blower supports positive and negative duct tests.

Closed-loop control maintains the selected test pressure.

Calibrated inlet measurement quantifies stabilizing leakage airflow.

Dual pressure channels monitor duct pressure and flow element.

Guided controller calculates leakage rate and test duration.

Wheeled field enclosure organizes hose, cables and adapters.

Kunden Produktbedenken

Duct leakage must be quantified at a stable specified pressure even though the system response changes with seal quality, section size and test direction.

Test pressure drifts as leakage changes during the run.Closed-loop blower control continuously adjusts flow to maintain the selected pressure.
One-direction equipment cannot assess both supply and extract ductwork.A reversible flow arrangement supports positive and negative pressure tests.
Leakage calculations vary when technicians use separate instruments.Integrated pressure and calibrated-flow channels calculate leakage within one guided workflow.
Large test equipment is difficult to move through an active site.A compact wheeled enclosure and stored flexible hose simplify relocation between duct sections.

Typische Anwendungen

Cleanroom supply-duct leakage testingExhaust and return duct commissioningNew ductwork quality verificationPost-repair airtightness checksHVAC leakage-class documentation

Technische Parameter

Representative portable leakage-tester construction is shown below; blower capacity, calibrated flow range and hose size can be selected for the duct sections under test.

Core MaterialVariable-speed centrifugal blower, calibrated flow nozzle, pressure sensors and powder-coated steel enclosure
Panel DickeTypically 1.0-2.0 mm for the steel cabinet panels
Effektive BreiteApproximately 450-650 mm across the mobile enclosure
Maximale LängeApproximately 700-1000 mm including wheeled cabinet and stored hose
Stahl facing DickeTypically 1.0-2.0 mm for powder-coated steel enclosure panels
KerndichteApproximately 7850 kg/m³ for structural steel components
Thermische LeitfähigkeitApproximately 45-55 W/(m·K) for structural steel components
Oberfläche FinishSafety-yellow powder-coated cabinet with graphite controls, black hose and stainless fittings
Gemeinsamer TypCam-lock flexible duct connection with sealed calibrated inlet and barbed pressure taps
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Low- or high-flow configurationPositive/negative test modeMultiple calibrated flow nozzlesFlexible connection hose sizesReport download and printingTransportschutzdeckung