Nhà cung cấp một cửa của bạn cho thiết bị phòng sạch và thiết bị vô trùng cơ sở thiết yếuHỗ trợ dự án quốc tế
Open mobile navigationClose mobile navigation
Dụng cụ kiểm tra và xác nhận phòng sạch

Máy kiểm tra rò rỉ ống

A portable positive/negative duct leakage tester with variable blower, calibrated flow measurement and automatic pressure control for HVAC commissioning.
  • Controlled positive and negative duct pressurization.
  • Calibrated leakage-flow measurement.
  • Portable integrated field test system.
Yêu cầu báo giá Duyệt các sản phẩm

Giới thiệu Sản phẩm

This self-contained tester connects to an isolated duct section, raises or lowers it to a defined pressure and measures the airflow required to hold that condition. A variable-speed blower, calibrated inlet and dual pressure channels allow the controller to calculate leakage rate during positive or negative tests. The wheeled enclosure and flexible test hose support field commissioning across large installations.

Các tính năng chính

Reversible blower supports positive and negative duct tests.

Closed-loop control maintains the selected test pressure.

Calibrated inlet measurement quantifies stabilizing leakage airflow.

Dual pressure channels monitor duct pressure and flow element.

Guided controller calculates leakage rate and test duration.

Wheeled field enclosure organizes hose, cables and adapters.

Các mối quan tâm về sản phẩm của khách hàng

Duct leakage must be quantified at a stable specified pressure even though the system response changes with seal quality, section size and test direction.

Test pressure drifts as leakage changes during the run.Closed-loop blower control continuously adjusts flow to maintain the selected pressure.
One-direction equipment cannot assess both supply and extract ductwork.A reversible flow arrangement supports positive and negative pressure tests.
Leakage calculations vary when technicians use separate instruments.Integrated pressure and calibrated-flow channels calculate leakage within one guided workflow.
Large test equipment is difficult to move through an active site.A compact wheeled enclosure and stored flexible hose simplify relocation between duct sections.

Các ứng dụng điển hình

Cleanroom supply-duct leakage testingExhaust and return duct commissioningNew ductwork quality verificationPost-repair airtightness checksHVAC leakage-class documentation

Thông số kỹ thuật

Representative portable leakage-tester construction is shown below; blower capacity, calibrated flow range and hose size can be selected for the duct sections under test.

Vật liệu lõiVariable-speed centrifugal blower, calibrated flow nozzle, pressure sensors and powder-coated steel enclosure
Độ dày bảng điều khiểnTypically 1.0-2.0 mm for the steel cabinet panels
Chiều rộng hiệu quảApproximately 450-650 mm across the mobile enclosure
Chiều dài tối đaApproximately 700-1000 mm including wheeled cabinet and stored hose
Thép đối mặt với độ dàyTypically 1.0-2.0 mm for powder-coated steel enclosure panels
Mật độ lõiApproximately 7850 kg/m³ for structural steel components
Độ dẫn nhiệtApproximately 45-55 W/(m·K) for structural steel components
Kết thúc bề mặtSafety-yellow powder-coated cabinet with graphite controls, black hose and stainless fittings
Loại khớp nốiCam-lock flexible duct connection with sealed calibrated inlet and barbed pressure taps
Tùy chỉnhCó sẵn dựa trên ứng dụng dự định và môi trường hoạt động.

Các tùy chọn có sẵn

Low- or high-flow configurationPositive/negative test modeMultiple calibrated flow nozzlesFlexible connection hose sizesReport download and printingBảo vệ vỏ vận tải

Planning a Duct Leakage Tester specification?

Gửi cho chúng tôi kích thước của bạn, điều kiện lắp đặt, mục tiêu hiệu suất và bề mặt yêu cầu hoàn thiện.

Nói chuyện với đội ngũ của chúng tôi
Email cho chúng tôi WhatsApp WeChat

Trang chủ

Sản phẩm

Tin tức

Về chúng tôi

Liên hệ