Duct اختبار تسرب

A portable positive/negative duct leakage tester with variable blower, calibrated flow measurement and automatic pressure control for HVAC commissioning.
  • Controlled positive and negative duct pressurization.
  • Calibrated leakage-flow measurement.
  • Portable integrated field test system.
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

This self-contained tester connects to an isolated duct section, raises or lowers it to a defined pressure and measures the airflow required to hold that condition. A variable-speed blower, calibrated inlet and dual pressure channels allow the controller to calculate leakage rate during positive or negative tests. The wheeled enclosure and flexible test hose support field commissioning across large installations.

الخصائص الرئيسية

Reversible blower supports positive and negative duct tests.

Closed-loop control maintains the selected test pressure.

Calibrated inlet measurement quantifies stabilizing leakage airflow.

Dual pressure channels monitor duct pressure and flow element.

Guided controller calculates leakage rate and test duration.

Wheeled field enclosure organizes hose, cables and adapters.

مخاوف المنتج للعملاء

Duct leakage must be quantified at a stable specified pressure even though the system response changes with seal quality, section size and test direction.

Test pressure drifts as leakage changes during the run.Closed-loop blower control continuously adjusts flow to maintain the selected pressure.
One-direction equipment cannot assess both supply and extract ductwork.A reversible flow arrangement supports positive and negative pressure tests.
Leakage calculations vary when technicians use separate instruments.Integrated pressure and calibrated-flow channels calculate leakage within one guided workflow.
Large test equipment is difficult to move through an active site.A compact wheeled enclosure and stored flexible hose simplify relocation between duct sections.

تطبيقات نموذجية

Cleanroom supply-duct leakage testingExhaust and return duct commissioningNew ductwork quality verificationPost-repair airtightness checksHVAC leakage-class documentation

المعلمات الفنية

Representative portable leakage-tester construction is shown below; blower capacity, calibrated flow range and hose size can be selected for the duct sections under test.

المواد الأساسيةVariable-speed centrifugal blower, calibrated flow nozzle, pressure sensors and powder-coated steel enclosure
سمك اللوحةTypically 1.0-2.0 mm for the steel cabinet panels
العرض الفعالApproximately 450-650 mm across the mobile enclosure
الحد الأقصى الطولApproximately 700-1000 mm including wheeled cabinet and stored hose
الصلب يواجه سمكTypically 1.0-2.0 mm for powder-coated steel enclosure panels
الكثافة الأساسيةApproximately 7850 kg/m³ for structural steel components
الموصلية الحراريةApproximately 45-55 W/(m·K) for structural steel components
إنهاء السطحSafety-yellow powder-coated cabinet with graphite controls, black hose and stainless fittings
نوع المشتركCam-lock flexible duct connection with sealed calibrated inlet and barbed pressure taps
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Low- or high-flow configurationPositive/negative test modeMultiple calibrated flow nozzlesFlexible connection hose sizesReport download and printingغطاء نقل واقي