Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Temiz Oda Test ve Validasyon Aletleri

Duct Leakage Tester

A portable positive/negative duct leakage tester with variable blower, calibrated flow measurement and automatic pressure control for HVAC commissioning.
  • Controlled positive and negative duct pressurization.
  • Calibrated leakage-flow measurement.
  • Portable integrated field test system.
Alıntı isteği Browse ürünleri

Ürün tanıtımı

This self-contained tester connects to an isolated duct section, raises or lowers it to a defined pressure and measures the airflow required to hold that condition. A variable-speed blower, calibrated inlet and dual pressure channels allow the controller to calculate leakage rate during positive or negative tests. The wheeled enclosure and flexible test hose support field commissioning across large installations.

Ana Özellikler

Reversible blower supports positive and negative duct tests.

Closed-loop control maintains the selected test pressure.

Calibrated inlet measurement quantifies stabilizing leakage airflow.

Dual pressure channels monitor duct pressure and flow element.

Guided controller calculates leakage rate and test duration.

Wheeled field enclosure organizes hose, cables and adapters.

Müşteri Ürün Sorunları

Duct leakage must be quantified at a stable specified pressure even though the system response changes with seal quality, section size and test direction.

Test pressure drifts as leakage changes during the run.Closed-loop blower control continuously adjusts flow to maintain the selected pressure.
One-direction equipment cannot assess both supply and extract ductwork.A reversible flow arrangement supports positive and negative pressure tests.
Leakage calculations vary when technicians use separate instruments.Integrated pressure and calibrated-flow channels calculate leakage within one guided workflow.
Large test equipment is difficult to move through an active site.A compact wheeled enclosure and stored flexible hose simplify relocation between duct sections.

Tipik uygulamalar

Cleanroom supply-duct leakage testingExhaust and return duct commissioningNew ductwork quality verificationPost-repair airtightness checksHVAC leakage-class documentation

Teknik parametreler

Representative portable leakage-tester construction is shown below; blower capacity, calibrated flow range and hose size can be selected for the duct sections under test.

Temel malzemelerVariable-speed centrifugal blower, calibrated flow nozzle, pressure sensors and powder-coated steel enclosure
Panel kalınlığıTypically 1.0-2.0 mm for the steel cabinet panels
Effective Width (Etkili Genişlik)Approximately 450-650 mm across the mobile enclosure
Maksimum uzunlukApproximately 700-1000 mm including wheeled cabinet and stored hose
Çelik yüz yüze kalınlığıTypically 1.0-2.0 mm for powder-coated steel enclosure panels
Core Density (Çekirdek Yoğunluğu)Approximately 7850 kg/m³ for structural steel components
Termal İletkenlikApproximately 45-55 W/(m·K) for structural steel components
Yüzey bitirmeSafety-yellow powder-coated cabinet with graphite controls, black hose and stainless fittings
Ortak tipCam-lock flexible duct connection with sealed calibrated inlet and barbed pressure taps
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Low- or high-flow configurationPositive/negative test modeMultiple calibrated flow nozzlesFlexible connection hose sizesReport download and printingKoruyucu taşıma kapakları

Planning a Duct Leakage Tester specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim