Introdução do produto
Two pressurised side plenums form the core of this double-sided air shower. Their opposed nozzle arrays provide cleaning air from both sides of the operator while screened lower returns collect the released particles. The layout is designed for facilities that require fuller all-around garment coverage than a one-wall air shower but retain a one-person entrance route.
Características-chave
Individually aimable outlets support adjustment for different garment lengths.
Two return paths collect air from both sides of the passage.
Removable inner access panels simplify cleaning of the nozzle and return surfaces.
Straight-through door alignment gives operators an intuitive direction of travel.
Preocupações do produto do cliente
Two active walls must improve body coverage while keeping airflow distribution and service access manageable.
One-sided airflow leaves protected surfaces on the far side of the operator.Matched arrays on the two sidewalls deliver air from opposing directions in the same cycle.
One side may feel stronger when the plenums are not balanced.Separate fan branches and balancing adjustments can equalise the two nozzle banks.
Crossing air streams may keep particles in the central passage.Paired low-level returns remove the contaminated air along both walls.
Internal maintenance disrupts the occupied passage.Serviceable nozzle panels provide access without dismantling the outer enclosure.
Aplicações típicas
Semiconductor gowning routesOptics manufacturing cleanroomsSterile-packaging accessPrecision assembly laboratories
Parâmetros técnicos
The following ranges suit a double-sided one-person cleaning chamber.
| Material principal | Mineral-wool insulated steel shell with two stainless nozzle banks, dual prefilters and H13 final filtration |
|---|---|
| Painel de espessura | 50 mm insulated side and roof panels |
| Largura efetiva | 800-1000 mm clear operator passage width |
| Comprimento máximo | Up to 1500 mm straight-through enclosure length |
| Aço enfrentando espessura | 1.0-1.2 mm powder-coated steel or stainless facing |
| Densidade Core | 80-100 kg/m³ mineral-wool panel infill |
| Condutividade térmica | 0.035-0.045 W/(m·K) for the mineral-wool insulation layer |
| Superfície acabado | Low-sheen white powder coat with brushed stainless nozzle plates |
| Tipo conjunto | Flush panel seams with sealed twin-plenum access panels and interlocked doors |
| Customização | Disponível com base na aplicação pretendida e no ambiente operacional. |
Opções disponíveis
Twin 6-9 nozzle side arraysPowder-coated or stainless enclosureAirflow adjustment controllerCycle-status display
Planning a Double-Sided Single-Person Air Shower specification?
Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Inglês
Alemão
Língua árabe
Francês
Língua indonésia
Japonês
Coreano
Língua malaia
Portuguêsatual
Língua russa
Espanhol
Tailandês
Língua turca
Vietnã