Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Sistemas de Distribuição de Ar para Sala Limpa / Cleanroom HEPA Supply Air Terminal
Sistemas de Distribuição de Ar para Sala Limpa

Z Sala limpa HEPA Terminal de suprimento de ar

A flush ceiling supply terminal that combines a gasket- or gel-sealed HEPA filter, cleanable diffuser face and room-side test access in one final air outlet.
  • Room-Side HEPA Filtration
  • Sealed Filter Interface
  • Cleanable Flush Face
  • Integrated Test Access
Solicite um orçamento. Browse produtos

Introdução do produto

The cleanroom HEPA supply air terminal places the final filter at the boundary between the supply duct and the controlled room. A welded steel housing receives the filter against a continuous gasket or gel channel, preventing untreated plenum air from bypassing the media. The removable diffuser face can produce radial, low-turbulence or vertical discharge while leaving the filter accessible from below. Upstream aerosol and pressure ports allow integrity testing and resistance checks without disturbing the ceiling seal.

Características-chave

The terminal filter seat applies uniform perimeter compression or gel engagement around the complete HEPA frame.

Room-side removal avoids opening the interstitial ceiling space during routine filter replacement.

Dedicated upstream sample and pressure ports support filter testing from the controlled side of the room.

A smooth powder-coated diffuser face tolerates repeated wipe-down and detaches without exposing fibrous lining.

Preocupações do produto do cliente

A terminal HEPA outlet must prevent bypass, distribute filtered air predictably and allow filter service without damaging the clean ceiling boundary.

Unfiltered air leaks between the HEPA frame and the terminal housing.A continuous gasket or liquid-gel seal closes the full filter perimeter under even clamping pressure.
Filter testing requires drilling temporary ports through the housing.Factory-installed upstream aerosol and differential-pressure connections provide repeatable room-side access.
A diffuser pattern creates excessive velocity directly below the outlet.Interchangeable perforated, radial or low-turbulence faces match the discharge pattern to room duty.
Ceiling access is blocked by services above the terminal.The face panel, filter clamps and filter are all serviceable from the room side.

Aplicações típicas

Pharmaceutical cleanroomsHospital isolation and treatment roomsLaboratórios de BiotecnologiaMedical-device assembly suitesElectronics clean production areas

Parâmetros técnicos

Typical construction ranges for a room-side replaceable HEPA supply air terminal are summarized below.

Material principalGlass-microfiber HEPA media in an aluminum frame with polymer gasket or liquid-gel perimeter seal
Painel de espessura0.8–1.2 mm welded steel terminal housing
Largura efetiva305–610 mm nominal filter and ceiling-module width
Comprimento máximoUp to 1220 mm for rectangular terminal modules
Aço enfrentando espessura0.8–1.2 mm powder-coated steel casing and diffuser face
Densidade CoreApproximately 7850 kg/m³ for the steel housing and face-panel structure
Condutividade térmicaApproximately 45–60 W/(m·K) for the steel housing and face-panel structure
Superfície acabadoSmooth white epoxy-polyester powder coating with optional antimicrobial formulation
Tipo conjuntoGasket- or gel-sealed HEPA filter seat with flanged round or rectangular duct inlet
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

H13 or H14 HEPA filter configurationPerforated vertical-flow diffuser plateRadial or adjustable-nozzle diffuser faceIntegral pressure-loss transmitter