موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة توزيع الهواء في الغرف النظيفة

غرفة نظيفة HEPA توريد الهواء المحطة

A flush ceiling supply terminal that combines a gasket- or gel-sealed HEPA filter, cleanable diffuser face and room-side test access in one final air outlet.
  • Room-Side HEPA Filtration
  • Sealed Filter Interface
  • Cleanable Flush Face
  • Integrated Test Access
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The cleanroom HEPA supply air terminal places the final filter at the boundary between the supply duct and the controlled room. A welded steel housing receives the filter against a continuous gasket or gel channel, preventing untreated plenum air from bypassing the media. The removable diffuser face can produce radial, low-turbulence or vertical discharge while leaving the filter accessible from below. Upstream aerosol and pressure ports allow integrity testing and resistance checks without disturbing the ceiling seal.

الخصائص الرئيسية

The terminal filter seat applies uniform perimeter compression or gel engagement around the complete HEPA frame.

Room-side removal avoids opening the interstitial ceiling space during routine filter replacement.

Dedicated upstream sample and pressure ports support filter testing from the controlled side of the room.

A smooth powder-coated diffuser face tolerates repeated wipe-down and detaches without exposing fibrous lining.

مخاوف المنتج للعملاء

A terminal HEPA outlet must prevent bypass, distribute filtered air predictably and allow filter service without damaging the clean ceiling boundary.

Unfiltered air leaks between the HEPA frame and the terminal housing.A continuous gasket or liquid-gel seal closes the full filter perimeter under even clamping pressure.
Filter testing requires drilling temporary ports through the housing.Factory-installed upstream aerosol and differential-pressure connections provide repeatable room-side access.
A diffuser pattern creates excessive velocity directly below the outlet.Interchangeable perforated, radial or low-turbulence faces match the discharge pattern to room duty.
Ceiling access is blocked by services above the terminal.The face panel, filter clamps and filter are all serviceable from the room side.

تطبيقات نموذجية

Pharmaceutical cleanroomsHospital isolation and treatment roomsمختبرات التكنولوجيا الحيويةMedical-device assembly suitesElectronics clean production areas

المعلمات الفنية

Typical construction ranges for a room-side replaceable HEPA supply air terminal are summarized below.

المواد الأساسيةGlass-microfiber HEPA media in an aluminum frame with polymer gasket or liquid-gel perimeter seal
سمك اللوحة0.8–1.2 mm welded steel terminal housing
العرض الفعال305–610 mm nominal filter and ceiling-module width
الحد الأقصى الطولUp to 1220 mm for rectangular terminal modules
الصلب يواجه سمك0.8–1.2 mm powder-coated steel casing and diffuser face
الكثافة الأساسيةApproximately 7850 kg/m³ for the steel housing and face-panel structure
الموصلية الحراريةApproximately 45–60 W/(m·K) for the steel housing and face-panel structure
إنهاء السطحSmooth white epoxy-polyester powder coating with optional antimicrobial formulation
نوع المشتركGasket- or gel-sealed HEPA filter seat with flanged round or rectangular duct inlet
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

H13 or H14 HEPA filter configurationPerforated vertical-flow diffuser plateRadial or adjustable-nozzle diffuser faceIntegral pressure-loss transmitter

Planning a Cleanroom HEPA Supply Air Terminal specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat