Sala limpia HEPA suministro de aire terminal
- Room-Side HEPA Filtration
- Sealed Filter Interface
- Cleanable Flush Face
- Integrated Test Access
Introducción del producto
The cleanroom HEPA supply air terminal places the final filter at the boundary between the supply duct and the controlled room. A welded steel housing receives the filter against a continuous gasket or gel channel, preventing untreated plenum air from bypassing the media. The removable diffuser face can produce radial, low-turbulence or vertical discharge while leaving the filter accessible from below. Upstream aerosol and pressure ports allow integrity testing and resistance checks without disturbing the ceiling seal.
Características clave
Room-side removal avoids opening the interstitial ceiling space during routine filter replacement.
Dedicated upstream sample and pressure ports support filter testing from the controlled side of the room.
A smooth powder-coated diffuser face tolerates repeated wipe-down and detaches without exposing fibrous lining.
Preocupaciones del producto del cliente
A terminal HEPA outlet must prevent bypass, distribute filtered air predictably and allow filter service without damaging the clean ceiling boundary.
Aplicaciones típicas
Parámetros técnicos
Typical construction ranges for a room-side replaceable HEPA supply air terminal are summarized below.
| Materiales Core | Glass-microfiber HEPA media in an aluminum frame with polymer gasket or liquid-gel perimeter seal |
|---|---|
| Panel de espesor | 0.8–1.2 mm welded steel terminal housing |
| Ancho efectivo | 305–610 mm nominal filter and ceiling-module width |
| Longitud máxima | Up to 1220 mm for rectangular terminal modules |
| Acero frente a espesor | 0.8–1.2 mm powder-coated steel casing and diffuser face |
| Densidad Core | Approximately 7850 kg/m³ for the steel housing and face-panel structure |
| Conductividad térmica | Approximately 45–60 W/(m·K) for the steel housing and face-panel structure |
| Superficie acabada | Smooth white epoxy-polyester powder coating with optional antimicrobial formulation |
| Tipo conjunto | Gasket- or gel-sealed HEPA filter seat with flanged round or rectangular duct inlet |
| Customization | Disponible según la aplicación prevista y el entorno operativo. |
Opciones disponibles
Planning a Cleanroom HEPA Supply Air Terminal specification?
Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Inglés
Alemán
El árabe
Francés
Idioma indonesio
El japonés
Coreano
El malayo
El portugués
El ruso
EspañolCurrent
Tailandés
El turco
El vietnamita