Cleanroom HEPA Terminal d'alimentation en air
- Room-Side HEPA Filtration
- Sealed Filter Interface
- Cleanable Flush Face
- Integrated Test Access
Introduction de produit
The cleanroom HEPA supply air terminal places the final filter at the boundary between the supply duct and the controlled room. A welded steel housing receives the filter against a continuous gasket or gel channel, preventing untreated plenum air from bypassing the media. The removable diffuser face can produce radial, low-turbulence or vertical discharge while leaving the filter accessible from below. Upstream aerosol and pressure ports allow integrity testing and resistance checks without disturbing the ceiling seal.
Key Features
Room-side removal avoids opening the interstitial ceiling space during routine filter replacement.
Dedicated upstream sample and pressure ports support filter testing from the controlled side of the room.
A smooth powder-coated diffuser face tolerates repeated wipe-down and detaches without exposing fibrous lining.
Préoccupations du client produit
A terminal HEPA outlet must prevent bypass, distribute filtered air predictably and allow filter service without damaging the clean ceiling boundary.
Les applications typiques
Paramètres techniques
Typical construction ranges for a room-side replaceable HEPA supply air terminal are summarized below.
| Matériaux de base | Glass-microfiber HEPA media in an aluminum frame with polymer gasket or liquid-gel perimeter seal |
|---|---|
| Panneau épaisseur | 0.8–1.2 mm welded steel terminal housing |
| Largeur effective | 305–610 mm nominal filter and ceiling-module width |
| Longueur maximale | Up to 1220 mm for rectangular terminal modules |
| Acier face épaisseur | 0.8–1.2 mm powder-coated steel casing and diffuser face |
| Densité Core | Approximately 7850 kg/m³ for the steel housing and face-panel structure |
| Conductivité thermique | Approximately 45–60 W/(m·K) for the steel housing and face-panel structure |
| surface finie | Smooth white epoxy-polyester powder coating with optional antimicrobial formulation |
| Type joint | Gasket- or gel-sealed HEPA filter seat with flanged round or rectangular duct inlet |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Cleanroom HEPA Supply Air Terminal specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien