A flush ceiling supply terminal that combines a gasket- or gel-sealed HEPA filter, cleanable diffuser face and room-side test access in one final air outlet.
  • Room-Side HEPA Filtration
  • Sealed Filter Interface
  • Cleanable Flush Face
  • Integrated Test Access
Запрос котировки Просмотреть продукты

Введение продукции

The cleanroom HEPA supply air terminal places the final filter at the boundary between the supply duct and the controlled room. A welded steel housing receives the filter against a continuous gasket or gel channel, preventing untreated plenum air from bypassing the media. The removable diffuser face can produce radial, low-turbulence or vertical discharge while leaving the filter accessible from below. Upstream aerosol and pressure ports allow integrity testing and resistance checks without disturbing the ceiling seal.

Основные характеристики

The terminal filter seat applies uniform perimeter compression or gel engagement around the complete HEPA frame.

Room-side removal avoids opening the interstitial ceiling space during routine filter replacement.

Dedicated upstream sample and pressure ports support filter testing from the controlled side of the room.

A smooth powder-coated diffuser face tolerates repeated wipe-down and detaches without exposing fibrous lining.

Обеспокоенность клиентов продуктами

A terminal HEPA outlet must prevent bypass, distribute filtered air predictably and allow filter service without damaging the clean ceiling boundary.

Unfiltered air leaks between the HEPA frame and the terminal housing.A continuous gasket or liquid-gel seal closes the full filter perimeter under even clamping pressure.
Filter testing requires drilling temporary ports through the housing.Factory-installed upstream aerosol and differential-pressure connections provide repeatable room-side access.
A diffuser pattern creates excessive velocity directly below the outlet.Interchangeable perforated, radial or low-turbulence faces match the discharge pattern to room duty.
Ceiling access is blocked by services above the terminal.The face panel, filter clamps and filter are all serviceable from the room side.

Типичные приложения

Pharmaceutical cleanroomsHospital isolation and treatment roomsBiotechnology laboratoriesMedical-device assembly suitesElectronics clean production areas

Технические параметры

Typical construction ranges for a room-side replaceable HEPA supply air terminal are summarized below.

Основной материалGlass-microfiber HEPA media in an aluminum frame with polymer gasket or liquid-gel perimeter seal
Толщина панели0.8–1.2 mm welded steel terminal housing
эффективная ширина305–610 mm nominal filter and ceiling-module width
Максимальная длинаUp to 1220 mm for rectangular terminal modules
Толщина линий стали0.8–1.2 mm powder-coated steel casing and diffuser face
Плотность ядраApproximately 7850 kg/m³ for the steel housing and face-panel structure
ТеплопроводимостьApproximately 45–60 W/(m·K) for the steel housing and face-panel structure
Поверхностная отделкаSmooth white epoxy-polyester powder coating with optional antimicrobial formulation
Объединенный типGasket- or gel-sealed HEPA filter seat with flanged round or rectangular duct inlet
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

H13 or H14 HEPA filter configurationPerforated vertical-flow diffuser plateRadial or adjustable-nozzle diffuser faceIntegral pressure-loss transmitter