Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda Hava Dağıtım Sistemleri / Cleanroom HEPA Supply Air Terminal
Temiz Oda Hava Dağıtım Sistemleri

Temiz Oda HEPA Temizleme Hava Terminali

A flush ceiling supply terminal that combines a gasket- or gel-sealed HEPA filter, cleanable diffuser face and room-side test access in one final air outlet.
  • Room-Side HEPA Filtration
  • Sealed Filter Interface
  • Cleanable Flush Face
  • Integrated Test Access
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The cleanroom HEPA supply air terminal places the final filter at the boundary between the supply duct and the controlled room. A welded steel housing receives the filter against a continuous gasket or gel channel, preventing untreated plenum air from bypassing the media. The removable diffuser face can produce radial, low-turbulence or vertical discharge while leaving the filter accessible from below. Upstream aerosol and pressure ports allow integrity testing and resistance checks without disturbing the ceiling seal.

Ana Özellikler

The terminal filter seat applies uniform perimeter compression or gel engagement around the complete HEPA frame.

Room-side removal avoids opening the interstitial ceiling space during routine filter replacement.

Dedicated upstream sample and pressure ports support filter testing from the controlled side of the room.

A smooth powder-coated diffuser face tolerates repeated wipe-down and detaches without exposing fibrous lining.

Müşteri Ürün Sorunları

A terminal HEPA outlet must prevent bypass, distribute filtered air predictably and allow filter service without damaging the clean ceiling boundary.

Unfiltered air leaks between the HEPA frame and the terminal housing.A continuous gasket or liquid-gel seal closes the full filter perimeter under even clamping pressure.
Filter testing requires drilling temporary ports through the housing.Factory-installed upstream aerosol and differential-pressure connections provide repeatable room-side access.
A diffuser pattern creates excessive velocity directly below the outlet.Interchangeable perforated, radial or low-turbulence faces match the discharge pattern to room duty.
Ceiling access is blocked by services above the terminal.The face panel, filter clamps and filter are all serviceable from the room side.

Tipik uygulamalar

Pharmaceutical cleanroomsHospital isolation and treatment roomsBiyoteknoloji LaboratuvarlarıMedical-device assembly suitesElectronics clean production areas

Teknik parametreler

Typical construction ranges for a room-side replaceable HEPA supply air terminal are summarized below.

Temel malzemelerGlass-microfiber HEPA media in an aluminum frame with polymer gasket or liquid-gel perimeter seal
Panel kalınlığı0.8–1.2 mm welded steel terminal housing
Effective Width (Etkili Genişlik)305–610 mm nominal filter and ceiling-module width
Maksimum uzunlukUp to 1220 mm for rectangular terminal modules
Çelik yüz yüze kalınlığı0.8–1.2 mm powder-coated steel casing and diffuser face
Core Density (Çekirdek Yoğunluğu)Approximately 7850 kg/m³ for the steel housing and face-panel structure
Termal İletkenlikApproximately 45–60 W/(m·K) for the steel housing and face-panel structure
Yüzey bitirmeSmooth white epoxy-polyester powder coating with optional antimicrobial formulation
Ortak tipGasket- or gel-sealed HEPA filter seat with flanged round or rectangular duct inlet
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

H13 or H14 HEPA filter configurationPerforated vertical-flow diffuser plateRadial or adjustable-nozzle diffuser faceIntegral pressure-loss transmitter

Planning a Cleanroom HEPA Supply Air Terminal specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat

Ana Sayfa

Ürünler

Haberler

Hakkımızda

İletişim