Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
ST STSTjh CleanroomOpen mobile navigationClose mobile navigation
Cleanroom HVAC dan Peralatan Penanganan Udara

Unit Penanganan Udara Ruang Bersih

A low-leakage hygienic air handler designed to filter, cool, heat and condition supply air for pressure-controlled clean production spaces.
  • Smooth Hygienic Interior
  • Filtrasi multi-tahap
  • Controlled Supply Air
  • Condensation-Resistant Casing
Permintaan untuk kutipan Browse Produk

Perkenalan produk

A cleanroom air handling unit conditions the large, stable airflow needed to control temperature, humidity, pressure cascade and particle transport. The casing uses flush cleanable inner panels, sealed access doors, drainable coil sections and corrosion-resistant hardware. Prefilters protect the coil and downstream final filters, while direct-drive fans modulate against filter loading and room-pressure demand. Coil face velocity, condensate drainage and access clearances are selected to prevent water carryover into downstream sections.

Fitur utama:

Flush internal surfaces reduce exposed ledges around filters, coils and service doors.

Separated prefilter and fine-filter stages protect coils and extend the useful life of downstream final filters.

Sloped stainless-steel drain pans remove condensate from cooling-coil sections without standing water.

Variable-speed direct-drive fans maintain scheduled airflow as filters load and operating modes change.

Kekhawatiran produk pelanggan

Particle control depends on the entire supply-air path remaining clean, dry and pressure-stable through changing filter and thermal loads.

Dust accumulates on internal ledges that are difficult to reach during sanitation.Flush inner panels and removable components leave broad surfaces accessible for wipe-down.
Cooling-coil condensate remains in the unit and supports odor or microbial growth.A sloped stainless drain pan and correctly trapped drain evacuate water from the wet section.
Rising filter resistance reduces room air changes and destabilizes pressure.Fan-speed control responds to airflow or static-pressure feedback across the operating filter range.
Air bypasses the final filter because the holding frame is not uniformly sealed.Gasketed filter tracks apply even compression around each selected filter module.

Aplikasi yang Tipis

Sterile pharmaceutical manufacturingBiological laboratoriesPerangkat medis bersih perakitanSemiconductor support cleanroomsHospital clean treatment areas

Parameter teknis

The following ranges describe a typical hygienic double-skin AHU for cleanroom service.

Bahan intiClosed-cell polyurethane or non-shedding mineral-wool casing insulation
Ketebalan Panel (Panel Thickness)50–60 mm double-skin hygienic panel
Efektif lebar900–3600 mm nominal unit width
Panjang maksimumUp to 11000 mm with gasketed modular sections
Baja menghadap ketebalan0.6–1.0 mm outer skin and 0.8–1.0 mm cleanable inner skin
Kepadatan inti (core density)40–44 kg/m³ polyurethane or 82–100 kg/m³ mineral wool
Konduktivitas Termal (Thermal Conductivity)0.022–0.038 W/(m·K) for the insulated casing core
Permukaan selesaiPowder-coated exterior with smooth galvanized, coated or 304 stainless-steel interior
Jenis BersamaFlush gasketed panels on thermal-break frame with sealed filter and access-door interfaces
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

304 or 316L stainless-steel wet-section liningEC fan wall with airflow measurementHeating, cooling and reheat coil combinationsPrefilter, fine-filter and HEPA housing stages

Planning a Cleanroom Air Handling Unit specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami