موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
معدات الغرف النظيفة المحددة للصناعة

RABS نظام الحاجز

A modular stainless barrier that combines clear physical separation, glove access and HEPA unidirectional airflow around an aseptic filling or handling line.
  • Controlled Physical Barrier
  • HEPA First-Air Protection
  • Interlocked Access Doors
  • Retrofit-Ready Modules
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The restricted access barrier system surrounds an aseptic process with stainless posts, clear panels and monitored access doors while preserving integration with the filling conveyor. Unidirectional HEPA airflow protects the critical zone, and glove ports provide controlled intervention points. Modular wall, door and filter sections can be arranged around new or existing equipment, with transfer ports and door monitoring incorporated where required.

الخصائص الرئيسية

Clear fixed barriers separate personnel from exposed product while retaining process visibility.

Top-mounted HEPA modules provide unidirectional airflow over the critical process path.

Interlocked doors and defined glove ports control and document manual intervention.

Modular posts and panels adapt to conveyor, filler and retrofit geometries.

مخاوف المنتج للعملاء

Open filling lines expose critical product paths to operator movement and uncontrolled interventions even within a cleanroom.

Personnel movement can disturb first air and introduce contaminants.Clear barriers and fixed glove ports physically separate operators from the process path.
Uncontrolled door opening compromises the protected zone.Monitored interlocks restrict access and record defined interventions.
Existing machinery has irregular access and conveyor geometry.Modular frames, panels and pass-throughs are configured around the installed equipment.
Materials need controlled entry without opening large doors.Rapid transfer ports or dedicated small transfer interfaces support localized introduction.

تطبيقات نموذجية

Aseptic vial and syringe fillingStoppering and capping linesSterile component handlingRetrofit protection for existing filling equipment

المعلمات الفنية

Typical construction values for a modular pharmaceutical RABS are listed below.

المواد الأساسية316L stainless steel framework with laminated safety-glass or clear polymer barrier panels
سمك اللوحة8-15 mm transparent barrier panels
العرض الفعال1200-3000 mm protected process width
الحد الأقصى الطولUp to 12000 mm modular line length
الصلب يواجه سمك1.2-1.5 mm stainless cladding and service panels
الكثافة الأساسية2400-2500 kg/m³ for safety-glass barrier panels
الموصلية الحرارية0.8-1.0 W/(m·K) for laminated glass panels
إنهاء السطحSatin stainless steel with flush clear barriers and cleanable seals
نوع المشتركBolted modular stainless frame with gasketed interlocked doors, sealed HEPA plenums and conveyor pass-through interfaces
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Open or closed RABS configurationActive or passive HEPA airflowRapid transfer and aseptic liquid portsDoor monitoring, PLC and audit trail

Planning a RABS Barrier System specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا