Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Equipos de sala limpia específicos de la industria

Sistema de barreras RABS por

A modular stainless barrier that combines clear physical separation, glove access and HEPA unidirectional airflow around an aseptic filling or handling line.
  • Controlled Physical Barrier
  • HEPA First-Air Protection
  • Interlocked Access Doors
  • Retrofit-Ready Modules
Solicite un presupuesto. Browse productos

Introducción del producto

The restricted access barrier system surrounds an aseptic process with stainless posts, clear panels and monitored access doors while preserving integration with the filling conveyor. Unidirectional HEPA airflow protects the critical zone, and glove ports provide controlled intervention points. Modular wall, door and filter sections can be arranged around new or existing equipment, with transfer ports and door monitoring incorporated where required.

Características clave

Clear fixed barriers separate personnel from exposed product while retaining process visibility.

Top-mounted HEPA modules provide unidirectional airflow over the critical process path.

Interlocked doors and defined glove ports control and document manual intervention.

Modular posts and panels adapt to conveyor, filler and retrofit geometries.

Preocupaciones del producto del cliente

Open filling lines expose critical product paths to operator movement and uncontrolled interventions even within a cleanroom.

Personnel movement can disturb first air and introduce contaminants.Clear barriers and fixed glove ports physically separate operators from the process path.
Uncontrolled door opening compromises the protected zone.Monitored interlocks restrict access and record defined interventions.
Existing machinery has irregular access and conveyor geometry.Modular frames, panels and pass-throughs are configured around the installed equipment.
Materials need controlled entry without opening large doors.Rapid transfer ports or dedicated small transfer interfaces support localized introduction.

Aplicaciones típicas

Aseptic vial and syringe fillingStoppering and capping linesSterile component handlingRetrofit protection for existing filling equipment

Parámetros técnicos

Typical construction values for a modular pharmaceutical RABS are listed below.

Materiales Core316L stainless steel framework with laminated safety-glass or clear polymer barrier panels
Panel de espesor8-15 mm transparent barrier panels
Ancho efectivo1200-3000 mm protected process width
Longitud máximaUp to 12000 mm modular line length
Acero frente a espesor1.2-1.5 mm stainless cladding and service panels
Densidad Core2400-2500 kg/m³ for safety-glass barrier panels
Conductividad térmica0.8-1.0 W/(m·K) for laminated glass panels
Superficie acabadaSatin stainless steel with flush clear barriers and cleanable seals
Tipo conjuntoBolted modular stainless frame with gasketed interlocked doors, sealed HEPA plenums and conveyor pass-through interfaces
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Open or closed RABS configurationActive or passive HEPA airflowRapid transfer and aseptic liquid portsDoor monitoring, PLC and audit trail

Planning a RABS Barrier System specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.

Habla con nuestro equipo
E-mail Nos WhatsApp WeChat