موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
معدات تهوية وتكييف ومعالجة الهواء في الغرف النظيفة

وحدة التحكم في درجة الحرارة والرطوبة الدقيقة

A close-control air-conditioning unit that coordinates cooling, reheat, humidification and airflow to hold stable cleanroom temperature and moisture conditions.
  • Coordinated Cooling and Reheat
  • Stable Humidity Control
  • Modulating Airflow
  • Remote Monitoring Ready
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The precision temperature and humidity control unit responds to small thermal and moisture changes that conventional comfort equipment may ignore. A modulating cooling stage removes sensible heat and moisture, reheat prevents overcooling during dehumidification, and humidification adds controlled moisture during dry conditions. Direct-drive fans maintain airflow through filter loading, while separate temperature and humidity sensors support stable control. The unit is suited to laboratories, metrology rooms and clean processes with narrow operating bands.

الخصائص الرئيسية

Cooling and reheat outputs are coordinated to control moisture without allowing room temperature to drift.

Modulating valves, inverter compressors or staged circuits provide finer response than simple on-off control.

Remote supply and return sensors can distinguish room conditions from local unit casing effects.

Trendable alarms for temperature, humidity, airflow and filter loading support early intervention.

مخاوف المنتج للعملاء

Tight environmental control requires all heating, cooling, humidifying and airflow functions to respond as one system rather than as independent devices.

Dehumidification lowers room temperature below the operating band.Modulating reheat offsets the sensible cooling remaining after moisture removal.
Oversized on-off cooling cycles cause repeated humidity swings.Variable or staged capacity matches smaller loads and reduces short cycling.
A sensor near the supply outlet does not represent the controlled workspace.Remote room sensors and averaged feedback are positioned at representative locations.
Filter loading changes airflow and alters coil moisture removal.Fan-speed control maintains airflow while differential-pressure monitoring signals service need.

تطبيقات نموذجية

Metrology and calibration roomsPharmaceutical laboratoriesMedical-device inspectionElectronics test cleanroomsStability and environmental rooms

المعلمات الفنية

Typical insulated casing construction for a precision environmental control unit is listed below.

المواد الأساسيةClosed-cell polyurethane insulation in thermally separated equipment panels
سمك اللوحة40–60 mm insulated casing panel
العرض الفعال700–2200 mm nominal unit width
الحد الأقصى الطولUp to 4500 mm overall equipment length
الصلب يواجه سمك0.6–1.0 mm coated steel casing skins
الكثافة الأساسية40–45 kg/m³ closed-cell polyurethane
الموصلية الحرارية0.023–0.026 W/(m·K) for precision-unit casing insulation
إنهاء السطحTextured powder-coated exterior with galvanized or stainless internal wet-section surfaces
نوع المشتركGasketed equipment panels with sealed coil section and flexible supply/return connections
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Chilled-water or inverter DX coolingElectric, hot-water or hot-gas reheatSteam or electrode humidifierDuty/standby fan or refrigeration circuit arrangement