ホーム / 製品 / クリーンルーム HVAC および空気処理装置 / Precision Temperature and Humidity Control Unit
クリーンルーム HVAC および空気処理装置

Precision 温度および湿度制御ユニット

A close-control air-conditioning unit that coordinates cooling, reheat, humidification and airflow to hold stable cleanroom temperature and moisture conditions.
  • Coordinated Cooling and Reheat
  • Stable Humidity Control
  • Modulating Airflow
  • Remote Monitoring Ready
見積もりリクエスト 製品案内

商品紹介

The precision temperature and humidity control unit responds to small thermal and moisture changes that conventional comfort equipment may ignore. A modulating cooling stage removes sensible heat and moisture, reheat prevents overcooling during dehumidification, and humidification adds controlled moisture during dry conditions. Direct-drive fans maintain airflow through filter loading, while separate temperature and humidity sensors support stable control. The unit is suited to laboratories, metrology rooms and clean processes with narrow operating bands.

主要な特徴

Cooling and reheat outputs are coordinated to control moisture without allowing room temperature to drift.

Modulating valves, inverter compressors or staged circuits provide finer response than simple on-off control.

Remote supply and return sensors can distinguish room conditions from local unit casing effects.

Trendable alarms for temperature, humidity, airflow and filter loading support early intervention.

お客様の製品に関する懸念事項

Tight environmental control requires all heating, cooling, humidifying and airflow functions to respond as one system rather than as independent devices.

Dehumidification lowers room temperature below the operating band.Modulating reheat offsets the sensible cooling remaining after moisture removal.
Oversized on-off cooling cycles cause repeated humidity swings.Variable or staged capacity matches smaller loads and reduces short cycling.
A sensor near the supply outlet does not represent the controlled workspace.Remote room sensors and averaged feedback are positioned at representative locations.
Filter loading changes airflow and alters coil moisture removal.Fan-speed control maintains airflow while differential-pressure monitoring signals service need.

典型的な用途

Metrology and calibration roomsPharmaceutical laboratoriesMedical-device inspectionElectronics test cleanroomsStability and environmental rooms

技術的なパラメータ

Typical insulated casing construction for a precision environmental control unit is listed below.

コア材料Closed-cell polyurethane insulation in thermally separated equipment panels
パネルの厚さ40–60 mm insulated casing panel
有効幅700–2200 mm nominal unit width
最大長さUp to 4500 mm overall equipment length
鋼鉄の厚さを直面する0.6–1.0 mm coated steel casing skins
コア密度40–45 kg/m³ closed-cell polyurethane
熱伝導率0.023–0.026 W/(m·K) for precision-unit casing insulation
表面仕上げTextured powder-coated exterior with galvanized or stainless internal wet-section surfaces
ジョイントタイプGasketed equipment panels with sealed coil section and flexible supply/return connections
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Chilled-water or inverter DX coolingElectric, hot-water or hot-gas reheatSteam or electrode humidifierDuty/standby fan or refrigeration circuit arrangement