Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Accueil / Produits / Salle blanche HVAC et équipement de manutention de l'air / Precision Temperature and Humidity Control Unit
Salle blanche HVAC et équipement de manutention de l'air

Unité de contrôle de température et d'humidité de précision

A close-control air-conditioning unit that coordinates cooling, reheat, humidification and airflow to hold stable cleanroom temperature and moisture conditions.
  • Coordinated Cooling and Reheat
  • Stable Humidity Control
  • Modulating Airflow
  • Remote Monitoring Ready
Demander un devis. Browse les produits

Introduction de produit

The precision temperature and humidity control unit responds to small thermal and moisture changes that conventional comfort equipment may ignore. A modulating cooling stage removes sensible heat and moisture, reheat prevents overcooling during dehumidification, and humidification adds controlled moisture during dry conditions. Direct-drive fans maintain airflow through filter loading, while separate temperature and humidity sensors support stable control. The unit is suited to laboratories, metrology rooms and clean processes with narrow operating bands.

Key Features

Cooling and reheat outputs are coordinated to control moisture without allowing room temperature to drift.

Modulating valves, inverter compressors or staged circuits provide finer response than simple on-off control.

Remote supply and return sensors can distinguish room conditions from local unit casing effects.

Trendable alarms for temperature, humidity, airflow and filter loading support early intervention.

Préoccupations du client produit

Tight environmental control requires all heating, cooling, humidifying and airflow functions to respond as one system rather than as independent devices.

Dehumidification lowers room temperature below the operating band.Modulating reheat offsets the sensible cooling remaining after moisture removal.
Oversized on-off cooling cycles cause repeated humidity swings.Variable or staged capacity matches smaller loads and reduces short cycling.
A sensor near the supply outlet does not represent the controlled workspace.Remote room sensors and averaged feedback are positioned at representative locations.
Filter loading changes airflow and alters coil moisture removal.Fan-speed control maintains airflow while differential-pressure monitoring signals service need.

Les applications typiques

Metrology and calibration roomsPharmaceutical laboratoriesMedical-device inspectionElectronics test cleanroomsStability and environmental rooms

Paramètres techniques

Typical insulated casing construction for a precision environmental control unit is listed below.

Matériaux de baseClosed-cell polyurethane insulation in thermally separated equipment panels
Panneau épaisseur40–60 mm insulated casing panel
Largeur effective700–2200 mm nominal unit width
Longueur maximaleUp to 4500 mm overall equipment length
Acier face épaisseur0.6–1.0 mm coated steel casing skins
Densité Core40–45 kg/m³ closed-cell polyurethane
Conductivité thermique0.023–0.026 W/(m·K) for precision-unit casing insulation
surface finieTextured powder-coated exterior with galvanized or stainless internal wet-section surfaces
Type jointGasketed equipment panels with sealed coil section and flexible supply/return connections
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Chilled-water or inverter DX coolingElectric, hot-water or hot-gas reheatSteam or electrode humidifierDuty/standby fan or refrigeration circuit arrangement