Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Beranda / Produk / Cleanroom HVAC dan Peralatan Penanganan Udara / Precision Temperature and Humidity Control Unit
Cleanroom HVAC dan Peralatan Penanganan Udara

Unit Kontrol Suhu dan Kelembaban Presisi

A close-control air-conditioning unit that coordinates cooling, reheat, humidification and airflow to hold stable cleanroom temperature and moisture conditions.
  • Coordinated Cooling and Reheat
  • Stable Humidity Control
  • Modulating Airflow
  • Remote Monitoring Ready
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The precision temperature and humidity control unit responds to small thermal and moisture changes that conventional comfort equipment may ignore. A modulating cooling stage removes sensible heat and moisture, reheat prevents overcooling during dehumidification, and humidification adds controlled moisture during dry conditions. Direct-drive fans maintain airflow through filter loading, while separate temperature and humidity sensors support stable control. The unit is suited to laboratories, metrology rooms and clean processes with narrow operating bands.

Fitur utama:

Cooling and reheat outputs are coordinated to control moisture without allowing room temperature to drift.

Modulating valves, inverter compressors or staged circuits provide finer response than simple on-off control.

Remote supply and return sensors can distinguish room conditions from local unit casing effects.

Trendable alarms for temperature, humidity, airflow and filter loading support early intervention.

Kekhawatiran produk pelanggan

Tight environmental control requires all heating, cooling, humidifying and airflow functions to respond as one system rather than as independent devices.

Dehumidification lowers room temperature below the operating band.Modulating reheat offsets the sensible cooling remaining after moisture removal.
Oversized on-off cooling cycles cause repeated humidity swings.Variable or staged capacity matches smaller loads and reduces short cycling.
A sensor near the supply outlet does not represent the controlled workspace.Remote room sensors and averaged feedback are positioned at representative locations.
Filter loading changes airflow and alters coil moisture removal.Fan-speed control maintains airflow while differential-pressure monitoring signals service need.

Aplikasi yang Tipis

Metrology and calibration roomsPharmaceutical laboratoriesMedical-device inspectionElectronics test cleanroomsStability and environmental rooms

Parameter teknis

Typical insulated casing construction for a precision environmental control unit is listed below.

Bahan intiClosed-cell polyurethane insulation in thermally separated equipment panels
Ketebalan Panel (Panel Thickness)40–60 mm insulated casing panel
Efektif lebar700–2200 mm nominal unit width
Panjang maksimumUp to 4500 mm overall equipment length
Baja menghadap ketebalan0.6–1.0 mm coated steel casing skins
Kepadatan inti (core density)40–45 kg/m³ closed-cell polyurethane
Konduktivitas Termal (Thermal Conductivity)0.023–0.026 W/(m·K) for precision-unit casing insulation
Permukaan selesaiTextured powder-coated exterior with galvanized or stainless internal wet-section surfaces
Jenis BersamaGasketed equipment panels with sealed coil section and flexible supply/return connections
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Chilled-water or inverter DX coolingElectric, hot-water or hot-gas reheatSteam or electrode humidifierDuty/standby fan or refrigeration circuit arrangement

Planning a Precision Temperature and Humidity Control Unit specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami