Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Temiz Oda HVAC ve Hava İşleme Ekipmanları / Precision Temperature and Humidity Control Unit
Temiz Oda HVAC ve Hava İşleme Ekipmanları

Hassas Sıcaklık ve Nem Kontrol Birimi

A close-control air-conditioning unit that coordinates cooling, reheat, humidification and airflow to hold stable cleanroom temperature and moisture conditions.
  • Coordinated Cooling and Reheat
  • Stable Humidity Control
  • Modulating Airflow
  • Remote Monitoring Ready
Alıntı isteği Browse ürünleri

Ürün tanıtımı

The precision temperature and humidity control unit responds to small thermal and moisture changes that conventional comfort equipment may ignore. A modulating cooling stage removes sensible heat and moisture, reheat prevents overcooling during dehumidification, and humidification adds controlled moisture during dry conditions. Direct-drive fans maintain airflow through filter loading, while separate temperature and humidity sensors support stable control. The unit is suited to laboratories, metrology rooms and clean processes with narrow operating bands.

Ana Özellikler

Cooling and reheat outputs are coordinated to control moisture without allowing room temperature to drift.

Modulating valves, inverter compressors or staged circuits provide finer response than simple on-off control.

Remote supply and return sensors can distinguish room conditions from local unit casing effects.

Trendable alarms for temperature, humidity, airflow and filter loading support early intervention.

Müşteri Ürün Sorunları

Tight environmental control requires all heating, cooling, humidifying and airflow functions to respond as one system rather than as independent devices.

Dehumidification lowers room temperature below the operating band.Modulating reheat offsets the sensible cooling remaining after moisture removal.
Oversized on-off cooling cycles cause repeated humidity swings.Variable or staged capacity matches smaller loads and reduces short cycling.
A sensor near the supply outlet does not represent the controlled workspace.Remote room sensors and averaged feedback are positioned at representative locations.
Filter loading changes airflow and alters coil moisture removal.Fan-speed control maintains airflow while differential-pressure monitoring signals service need.

Tipik uygulamalar

Metrology and calibration roomsPharmaceutical laboratoriesMedical-device inspectionElectronics test cleanroomsStability and environmental rooms

Teknik parametreler

Typical insulated casing construction for a precision environmental control unit is listed below.

Temel malzemelerClosed-cell polyurethane insulation in thermally separated equipment panels
Panel kalınlığı40–60 mm insulated casing panel
Effective Width (Etkili Genişlik)700–2200 mm nominal unit width
Maksimum uzunlukUp to 4500 mm overall equipment length
Çelik yüz yüze kalınlığı0.6–1.0 mm coated steel casing skins
Core Density (Çekirdek Yoğunluğu)40–45 kg/m³ closed-cell polyurethane
Termal İletkenlik0.023–0.026 W/(m·K) for precision-unit casing insulation
Yüzey bitirmeTextured powder-coated exterior with galvanized or stainless internal wet-section surfaces
Ortak tipGasketed equipment panels with sealed coil section and flexible supply/return connections
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Chilled-water or inverter DX coolingElectric, hot-water or hot-gas reheatSteam or electrode humidifierDuty/standby fan or refrigeration circuit arrangement

Planning a Precision Temperature and Humidity Control Unit specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.

Ekibimizle konuşun
E-posta Bize whatsapp WeChat