مقدمة المنتج

The cytotoxic isolator encloses hazardous drug manipulation inside a negative-pressure stainless chamber. Glove ports provide operator access, while an interlocked transfer chamber introduces materials without opening the main work zone. Exhaust air passes through staged high-efficiency filtration, and sharps, liquid and solid waste can leave through dedicated closed connections. The pressure and airflow arrangement prioritize personnel and environmental containment while maintaining a clean work zone for the product.

الخصائص الرئيسية

Negative pressure keeps leakage direction inward toward the filtered exhaust.

Glove manipulation separates the operator from hazardous drug aerosols and residues.

Staged exhaust filters provide redundant particulate retention.

A sealed transfer chamber limits direct room-to-work-zone openings.

Dedicated sharps and bag-out interfaces keep waste within closed routes.

مخاوف المنتج للعملاء

Hazardous drug work requires the work chamber, transfer route and waste system to maintain containment through the complete compounding cycle.

Waste containers leave the chamber through the clean supply route.Separate sharps, liquid and bag-out ports create dedicated egress paths.
A glove puncture weakens the primary barrier.Replaceable glove rings and integrity-test connections support routine barrier management.
Filter service exposes concentrated hazardous residue.Contained filter-change housings isolate loaded exhaust stages.
Pressure becomes positive during exhaust failure.Pressure monitoring and exhaust interlocks alarm or stop operation when containment is lost.

تطبيقات نموذجية

Cytotoxic drug compoundingAntineoplastic preparationHazardous sterile admixturesOncology pharmacy manipulation

المعلمات الفنية

Typical configurable construction ranges for a cytotoxic containment isolator are listed below.

المواد الأساسيةWelded SUS316L negative-pressure chamber with laminated glass, CSM gloves and staged safe-change exhaust filters
سمك اللوحة50-100 mm double-skin chamber and exhaust sections
العرض الفعال1200-3000 mm usable compounding width
الحد الأقصى الطولUp to 4500 mm overall isolator length
الصلب يواجه سمك2.0-3.0 mm SUS316L chamber; 1.2-1.5 mm service skins
الكثافة الأساسيةApproximately 8000 kg/m³ for SUS316L chamber material
الموصلية الحرارية14-16 W / (m · K) للفولاذ المقاوم للصدأ الأوستنيتي
إنهاء السطحElectropolished SUS316L interior with welded spill-retaining lower pan
نوع المشتركPressure-tight welded chamber with sealed glove rings, gasketed transfer hatch and contained exhaust-filter collars
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Two to four glove positionsSharps and liquid waste portsBag-out solid-waste systemIntegrated glove integrity tester

Planning a Cytotoxic Containment Isolator specification?

أرسل لنا الأبعاد الخاصة بك، شروط التثبيت، أهداف الأداء والتشطيب السطحي المطلوب.

تحدث مع فريقنا
E البريد الإلكتروني لنا WhatsApp WeChat

الرئيسية

المنتجات

الأخبار

من نحن

اتصل بنا