Isoleur de confinement cytotoxique
- Negative-Pressure Hazardous Drug Chamber
- Closed Glove Manipulation
- Staged Exhaust Filtration
- Contained Waste Egress
Introduction de produit
The cytotoxic isolator encloses hazardous drug manipulation inside a negative-pressure stainless chamber. Glove ports provide operator access, while an interlocked transfer chamber introduces materials without opening the main work zone. Exhaust air passes through staged high-efficiency filtration, and sharps, liquid and solid waste can leave through dedicated closed connections. The pressure and airflow arrangement prioritize personnel and environmental containment while maintaining a clean work zone for the product.
Key Features
Glove manipulation separates the operator from hazardous drug aerosols and residues.
Staged exhaust filters provide redundant particulate retention.
A sealed transfer chamber limits direct room-to-work-zone openings.
Dedicated sharps and bag-out interfaces keep waste within closed routes.
Préoccupations du client produit
Hazardous drug work requires the work chamber, transfer route and waste system to maintain containment through the complete compounding cycle.
Les applications typiques
Paramètres techniques
Typical configurable construction ranges for a cytotoxic containment isolator are listed below.
| Matériaux de base | Welded SUS316L negative-pressure chamber with laminated glass, CSM gloves and staged safe-change exhaust filters |
|---|---|
| Panneau épaisseur | 50-100 mm double-skin chamber and exhaust sections |
| Largeur effective | 1200-3000 mm usable compounding width |
| Longueur maximale | Up to 4500 mm overall isolator length |
| Acier face épaisseur | 2.0-3.0 mm SUS316L chamber; 1.2-1.5 mm service skins |
| Densité Core | Approximately 8000 kg/m³ for SUS316L chamber material |
| Conductivité thermique | 14 - 16 W / (m · K) pour l'acier inoxydable austénitique par |
| surface finie | Electropolished SUS316L interior with welded spill-retaining lower pan |
| Type joint | Pressure-tight welded chamber with sealed glove rings, gasketed transfer hatch and contained exhaust-filter collars |
| Customisation | Disponible en fonction de l'application prévue et de l'environnement d'exploitation. |
Options disponibles
Planning a Cytotoxic Containment Isolator specification?
Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Anglais
Allemand
Arabe
FrançaisCurrent
Indonésien
Japonais
Coréen
Le malais
Le portugais
russe
espagnol
Thaïlandais
Le turc
Le vietnamien