موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة التحكم في الغرف النظيفة والمراقبة البيئية

BACnet بوابة الاتصالات

An industrial gateway that maps cleanroom field-device data into BACnet objects for building automation, alarming, trending and supervision.
  • BACnet IP and MS/TP
  • Mapped BACnet Objects
  • COV Notification Support
  • Field Protocol Conversion
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The BACnet protocol gateway reads selected values from Modbus or other field devices and exposes them as named BACnet objects. Object type, instance, units, writable status and change-of-value behavior can be configured to match the building automation database. BACnet/IP Ethernet and BACnet MS/TP serial options allow connection to new or existing supervisory networks. Device discovery, object diagnostics and polling statistics help verify that cleanroom sensors, meters and equipment states are represented accurately without replacing their original controllers.

الخصائص الرئيسية

Field registers are mapped into structured BACnet analog, binary and multistate objects.

BACnet/IP and MS/TP options connect to different building automation network layers.

Change-of-value reporting reduces unnecessary polling for slowly changing room conditions.

Object and communication diagnostics identify mapping, timeout and discovery problems.

مخاوف المنتج للعملاء

Protocol conversion is successful only when engineering units, writable behavior and alarm meaning survive the register-to-object mapping.

Raw Modbus registers appear in the BMS without meaningful names or units.Configured BACnet objects assign descriptive names, units and object types to each value.
A read-only field value is accidentally exposed as writable.Object mapping explicitly controls command permissions and write behavior.
Continuous polling overloads a slower field network.Polling intervals and COV reporting balance freshness with serial-network capacity.
Duplicate BACnet device or object instances prevent discovery.Unique instance planning and built-in diagnostics expose address conflicts before integration.

تطبيقات نموذجية

Cleanroom BMS integrationEnvironmental sensor mappingEnergy meter BACnet conversionFFU and equipment status integration

المعلمات الفنية

Typical construction values for an industrial BACnet protocol gateway are listed below.

المواد الأساسيةFR-4 protocol processor with isolated interfaces in glass-filled flame-retardant polymer DIN-rail enclosure
سمك اللوحة90-140 mm gateway depth
العرض الفعال35-100 mm DIN-rail width
الحد الأقصى الطولUp to 170 mm housing height
الصلب يواجه سمك0 mm; non-metallic enclosure
الكثافة الأساسية1180-1550 kg/m³ for reinforced-polymer enclosure parts
الموصلية الحرارية0.19-0.40 W/(m·K) for polymer enclosure material
إنهاء السطحGray-blue reinforced-polymer housing with green BACnet and field-network LEDs
نوع المشتركDIN-rail clip with RJ45 BACnet/IP, removable MS/TP and field-bus terminals
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

BACnet/IP or MS/TPModbus RTU or TCP field sideCOV and alarm object mappingOptional metal enclosure