클린룸 제어 및 환경 모니터링 시스템 (Cleanroom Control and Environment Monitoring Systems)

BACnet 통신 게이트웨이

An industrial gateway that maps cleanroom field-device data into BACnet objects for building automation, alarming, trending and supervision.
  • BACnet IP and MS/TP
  • Mapped BACnet Objects
  • COV Notification Support
  • Field Protocol Conversion
견적 요청 제품 찾아보기

상품 소개

The BACnet protocol gateway reads selected values from Modbus or other field devices and exposes them as named BACnet objects. Object type, instance, units, writable status and change-of-value behavior can be configured to match the building automation database. BACnet/IP Ethernet and BACnet MS/TP serial options allow connection to new or existing supervisory networks. Device discovery, object diagnostics and polling statistics help verify that cleanroom sensors, meters and equipment states are represented accurately without replacing their original controllers.

주요 기능

Field registers are mapped into structured BACnet analog, binary and multistate objects.

BACnet/IP and MS/TP options connect to different building automation network layers.

Change-of-value reporting reduces unnecessary polling for slowly changing room conditions.

Object and communication diagnostics identify mapping, timeout and discovery problems.

고객 제품 관심사

Protocol conversion is successful only when engineering units, writable behavior and alarm meaning survive the register-to-object mapping.

Raw Modbus registers appear in the BMS without meaningful names or units.Configured BACnet objects assign descriptive names, units and object types to each value.
A read-only field value is accidentally exposed as writable.Object mapping explicitly controls command permissions and write behavior.
Continuous polling overloads a slower field network.Polling intervals and COV reporting balance freshness with serial-network capacity.
Duplicate BACnet device or object instances prevent discovery.Unique instance planning and built-in diagnostics expose address conflicts before integration.

일반적인 응용 프로그램

Cleanroom BMS integrationEnvironmental sensor mappingEnergy meter BACnet conversionFFU and equipment status integration

기술 매개변수

Typical construction values for an industrial BACnet protocol gateway are listed below.

핵심 재료FR-4 protocol processor with isolated interfaces in glass-filled flame-retardant polymer DIN-rail enclosure
패널 두께90-140 mm gateway depth
유효 폭35-100 mm DIN-rail width
최대 길이Up to 170 mm housing height
강철 면면 두께0 mm; non-metallic enclosure
코어 밀도1180-1550 kg/m³ for reinforced-polymer enclosure parts
열전도도 (Thermal Conductivity)0.19-0.40 W/(m·K) for polymer enclosure material
표면 마무리Gray-blue reinforced-polymer housing with green BACnet and field-network LEDs
접합 유형DIN-rail clip with RJ45 BACnet/IP, removable MS/TP and field-bus terminals
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

BACnet/IP or MS/TPModbus RTU or TCP field sideCOV and alarm object mappingOptional metal enclosure