Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Системы контроля за чистыми помещениями и экологического мониторинга

BACnet Communication Gateway

An industrial gateway that maps cleanroom field-device data into BACnet objects for building automation, alarming, trending and supervision.
  • BACnet IP and MS/TP
  • Mapped BACnet Objects
  • COV Notification Support
  • Field Protocol Conversion
Запрос котировки Просмотреть продукты

Введение продукции

The BACnet protocol gateway reads selected values from Modbus or other field devices and exposes them as named BACnet objects. Object type, instance, units, writable status and change-of-value behavior can be configured to match the building automation database. BACnet/IP Ethernet and BACnet MS/TP serial options allow connection to new or existing supervisory networks. Device discovery, object diagnostics and polling statistics help verify that cleanroom sensors, meters and equipment states are represented accurately without replacing their original controllers.

Основные характеристики

Field registers are mapped into structured BACnet analog, binary and multistate objects.

BACnet/IP and MS/TP options connect to different building automation network layers.

Change-of-value reporting reduces unnecessary polling for slowly changing room conditions.

Object and communication diagnostics identify mapping, timeout and discovery problems.

Обеспокоенность клиентов продуктами

Protocol conversion is successful only when engineering units, writable behavior and alarm meaning survive the register-to-object mapping.

Raw Modbus registers appear in the BMS without meaningful names or units.Configured BACnet objects assign descriptive names, units and object types to each value.
A read-only field value is accidentally exposed as writable.Object mapping explicitly controls command permissions and write behavior.
Continuous polling overloads a slower field network.Polling intervals and COV reporting balance freshness with serial-network capacity.
Duplicate BACnet device or object instances prevent discovery.Unique instance planning and built-in diagnostics expose address conflicts before integration.

Типичные приложения

Cleanroom BMS integrationEnvironmental sensor mappingEnergy meter BACnet conversionFFU and equipment status integration

Технические параметры

Typical construction values for an industrial BACnet protocol gateway are listed below.

Основной материалFR-4 protocol processor with isolated interfaces in glass-filled flame-retardant polymer DIN-rail enclosure
Толщина панели90-140 mm gateway depth
эффективная ширина35-100 mm DIN-rail width
Максимальная длинаUp to 170 mm housing height
Толщина линий стали0 mm; non-metallic enclosure
Плотность ядра1180-1550 kg/m³ for reinforced-polymer enclosure parts
Теплопроводимость0.19-0.40 W/(m·K) for polymer enclosure material
Поверхностная отделкаGray-blue reinforced-polymer housing with green BACnet and field-network LEDs
Объединенный типDIN-rail clip with RJ45 BACnet/IP, removable MS/TP and field-bus terminals
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

BACnet/IP or MS/TPModbus RTU or TCP field sideCOV and alarm object mappingOptional metal enclosure

Planning a BACnet Communication Gateway specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты