クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
クリーンルーム管理 · 環境モニタリングシステム

BACnet 通信ゲートウェイ

An industrial gateway that maps cleanroom field-device data into BACnet objects for building automation, alarming, trending and supervision.
  • BACnet IP and MS/TP
  • Mapped BACnet Objects
  • COV Notification Support
  • Field Protocol Conversion
見積もりリクエスト 製品案内

商品紹介

The BACnet protocol gateway reads selected values from Modbus or other field devices and exposes them as named BACnet objects. Object type, instance, units, writable status and change-of-value behavior can be configured to match the building automation database. BACnet/IP Ethernet and BACnet MS/TP serial options allow connection to new or existing supervisory networks. Device discovery, object diagnostics and polling statistics help verify that cleanroom sensors, meters and equipment states are represented accurately without replacing their original controllers.

主要な特徴

Field registers are mapped into structured BACnet analog, binary and multistate objects.

BACnet/IP and MS/TP options connect to different building automation network layers.

Change-of-value reporting reduces unnecessary polling for slowly changing room conditions.

Object and communication diagnostics identify mapping, timeout and discovery problems.

お客様の製品に関する懸念事項

Protocol conversion is successful only when engineering units, writable behavior and alarm meaning survive the register-to-object mapping.

Raw Modbus registers appear in the BMS without meaningful names or units.Configured BACnet objects assign descriptive names, units and object types to each value.
A read-only field value is accidentally exposed as writable.Object mapping explicitly controls command permissions and write behavior.
Continuous polling overloads a slower field network.Polling intervals and COV reporting balance freshness with serial-network capacity.
Duplicate BACnet device or object instances prevent discovery.Unique instance planning and built-in diagnostics expose address conflicts before integration.

典型的な用途

Cleanroom BMS integrationEnvironmental sensor mappingEnergy meter BACnet conversionFFU and equipment status integration

技術的なパラメータ

Typical construction values for an industrial BACnet protocol gateway are listed below.

コア材料FR-4 protocol processor with isolated interfaces in glass-filled flame-retardant polymer DIN-rail enclosure
パネルの厚さ90-140 mm gateway depth
有効幅35-100 mm DIN-rail width
最大長さUp to 170 mm housing height
鋼鉄の厚さを直面する0 mm; non-metallic enclosure
コア密度1180-1550 kg/m³ for reinforced-polymer enclosure parts
熱伝導率0.19-0.40 W/(m·K) for polymer enclosure material
表面仕上げGray-blue reinforced-polymer housing with green BACnet and field-network LEDs
ジョイントタイプDIN-rail clip with RJ45 BACnet/IP, removable MS/TP and field-bus terminals
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

BACnet/IP or MS/TPModbus RTU or TCP field sideCOV and alarm object mappingOptional metal enclosure

Planning a BACnet Communication Gateway specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ