BACnet Kommunikation Gateway

An industrial gateway that maps cleanroom field-device data into BACnet objects for building automation, alarming, trending and supervision.
  • BACnet IP and MS/TP
  • Mapped BACnet Objects
  • COV Notification Support
  • Field Protocol Conversion

Produkteinführung

The BACnet protocol gateway reads selected values from Modbus or other field devices and exposes them as named BACnet objects. Object type, instance, units, writable status and change-of-value behavior can be configured to match the building automation database. BACnet/IP Ethernet and BACnet MS/TP serial options allow connection to new or existing supervisory networks. Device discovery, object diagnostics and polling statistics help verify that cleanroom sensors, meters and equipment states are represented accurately without replacing their original controllers.

Key Features

Field registers are mapped into structured BACnet analog, binary and multistate objects.

BACnet/IP and MS/TP options connect to different building automation network layers.

Change-of-value reporting reduces unnecessary polling for slowly changing room conditions.

Object and communication diagnostics identify mapping, timeout and discovery problems.

Kunden Produktbedenken

Protocol conversion is successful only when engineering units, writable behavior and alarm meaning survive the register-to-object mapping.

Raw Modbus registers appear in the BMS without meaningful names or units.Configured BACnet objects assign descriptive names, units and object types to each value.
A read-only field value is accidentally exposed as writable.Object mapping explicitly controls command permissions and write behavior.
Continuous polling overloads a slower field network.Polling intervals and COV reporting balance freshness with serial-network capacity.
Duplicate BACnet device or object instances prevent discovery.Unique instance planning and built-in diagnostics expose address conflicts before integration.

Typische Anwendungen

Cleanroom BMS integrationEnvironmental sensor mappingEnergy meter BACnet conversionFFU and equipment status integration

Technische Parameter

Typical construction values for an industrial BACnet protocol gateway are listed below.

Core MaterialFR-4 protocol processor with isolated interfaces in glass-filled flame-retardant polymer DIN-rail enclosure
Panel Dicke90-140 mm gateway depth
Effektive Breite35-100 mm DIN-rail width
Maximale LängeUp to 170 mm housing height
Stahl facing Dicke0 mm; non-metallic enclosure
Kerndichte1180-1550 kg/m³ for reinforced-polymer enclosure parts
Thermische Leitfähigkeit0.19-0.40 W/(m·K) for polymer enclosure material
Oberfläche FinishGray-blue reinforced-polymer housing with green BACnet and field-network LEDs
Gemeinsamer TypDIN-rail clip with RJ45 BACnet/IP, removable MS/TP and field-bus terminals
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

BACnet/IP or MS/TPModbus RTU or TCP field sideCOV and alarm object mappingOptional metal enclosure

Planning a BACnet Communication Gateway specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.