Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Kontrol Cleanroom dan Sistem Pemantauan Lingkungan

Gateway Komunikasi BACnet

An industrial gateway that maps cleanroom field-device data into BACnet objects for building automation, alarming, trending and supervision.
  • BACnet IP and MS/TP
  • Mapped BACnet Objects
  • COV Notification Support
  • Field Protocol Conversion
Permintaan untuk kutipan Browse Produk

Perkenalan produk

The BACnet protocol gateway reads selected values from Modbus or other field devices and exposes them as named BACnet objects. Object type, instance, units, writable status and change-of-value behavior can be configured to match the building automation database. BACnet/IP Ethernet and BACnet MS/TP serial options allow connection to new or existing supervisory networks. Device discovery, object diagnostics and polling statistics help verify that cleanroom sensors, meters and equipment states are represented accurately without replacing their original controllers.

Fitur utama:

Field registers are mapped into structured BACnet analog, binary and multistate objects.

BACnet/IP and MS/TP options connect to different building automation network layers.

Change-of-value reporting reduces unnecessary polling for slowly changing room conditions.

Object and communication diagnostics identify mapping, timeout and discovery problems.

Kekhawatiran produk pelanggan

Protocol conversion is successful only when engineering units, writable behavior and alarm meaning survive the register-to-object mapping.

Raw Modbus registers appear in the BMS without meaningful names or units.Configured BACnet objects assign descriptive names, units and object types to each value.
A read-only field value is accidentally exposed as writable.Object mapping explicitly controls command permissions and write behavior.
Continuous polling overloads a slower field network.Polling intervals and COV reporting balance freshness with serial-network capacity.
Duplicate BACnet device or object instances prevent discovery.Unique instance planning and built-in diagnostics expose address conflicts before integration.

Aplikasi yang Tipis

Cleanroom BMS integrationEnvironmental sensor mappingEnergy meter BACnet conversionFFU and equipment status integration

Parameter teknis

Typical construction values for an industrial BACnet protocol gateway are listed below.

Bahan intiFR-4 protocol processor with isolated interfaces in glass-filled flame-retardant polymer DIN-rail enclosure
Ketebalan Panel (Panel Thickness)90-140 mm gateway depth
Efektif lebar35-100 mm DIN-rail width
Panjang maksimumUp to 170 mm housing height
Baja menghadap ketebalan0 mm; non-metallic enclosure
Kepadatan inti (core density)1180-1550 kg/m³ for reinforced-polymer enclosure parts
Konduktivitas Termal (Thermal Conductivity)0.19-0.40 W/(m·K) for polymer enclosure material
Permukaan selesaiGray-blue reinforced-polymer housing with green BACnet and field-network LEDs
Jenis BersamaDIN-rail clip with RJ45 BACnet/IP, removable MS/TP and field-bus terminals
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

BACnet/IP or MS/TPModbus RTU or TCP field sideCOV and alarm object mappingOptional metal enclosure

Planning a BACnet Communication Gateway specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami