موردك الموحد لمعدات الغرف النظيفة وأساسيات المرافق العقليةدعم المشاريع الدولية
Open mobile navigationClose mobile navigation
أنظمة التحكم في الغرف النظيفة والمراقبة البيئية

Aستشعار تدفق الهواء

A multi-point averaging sensor that samples total and static pressure across a duct and produces a stable differential signal for air-volume calculation.
  • Multi-Point Duct Averaging
  • Total and Static Pressure
  • Low Permanent Pressure Loss
  • External Tubing Ports
طلب عرض أسعار تصفح المنتجات

مقدمة المنتج

The duct airflow sensor uses perforated aluminum or stainless sensing tubes positioned across the duct cross-section. Upstream ports collect total pressure and separate ports collect static pressure; each set is internally averaged before reaching the external connectors. The resulting differential pressure represents mean duct velocity more reliably than a single-point pickup. Connected to a differential transmitter or controller, the sensor supports continuous volume-flow indication, alarm or closed-loop regulation without an active electronic element in the duct.

الخصائص الرئيسية

Multiple sensing ports average velocity variation across the duct cross-section.

Separate total and static chambers provide a continuous differential pressure signal.

Passive probe construction needs no power or electronics inside the airstream.

External barbed or compression fittings simplify connection to a remote transmitter.

مخاوف المنتج للعملاء

Single-point velocity readings often misrepresent total duct airflow when profiles are uneven after elbows, dampers or transitions.

A central pitot point misses high and low velocity regions across the duct.Distributed ports average the profile across multiple locations.
Electronics in the duct are difficult to service and expose wiring to airflow.The passive sensing grid sends only pneumatic signals to an external transmitter.
Tubing connections are inaccessible after ceiling closure.External manifolds place total and static fittings at a serviceable duct location.
Incorrect duct dimensions produce an inaccurate volume-flow value.The controller uses the actual duct area and measured differential to calculate airflow.

تطبيقات نموذجية

AHU supply airflow measurementCleanroom main-duct monitoringReturn-air volume trackingExhaust airflow control

المعلمات الفنية

Typical construction for a cleanroom duct averaging airflow sensor is listed below.

المواد الأساسية6063 anodized aluminum sensing tubes with galvanized steel or stainless mounting frame
سمك اللوحة25-60 mm sensing-tube depth
العرض الفعال200-1500 mm duct span
الحد الأقصى الطولUp to 1800 mm sensing-grid length
الصلب يواجه سمك1.2-1.6 mm galvanized or stainless mounting frame
الكثافة الأساسية2650-2750 kg/m³ for aluminum sensing elements
الموصلية الحرارية150-220 W/(m·K) for aluminum sensing tubes
إنهاء السطحNatural anodized aluminum tubes with clean zinc-coated or satin stainless frame
نوع المشتركDuct flange or insertion brackets with separated total-static pressure connectors
التخصيصمتوفر على أساس التطبيق المقصود وبيئة التشغيل.

الخيارات المتاحة

Cross-grid or single-span probeAluminum or stainless constructionCircular or rectangular duct fitBarbed or compression fittings