Sensor aliran udara

A multi-point averaging sensor that samples total and static pressure across a duct and produces a stable differential signal for air-volume calculation.
  • Multi-Point Duct Averaging
  • Total and Static Pressure
  • Low Permanent Pressure Loss
  • External Tubing Ports
Permintaan sebut harga Semak imbas produk

Pengenalan Produk

The duct airflow sensor uses perforated aluminum or stainless sensing tubes positioned across the duct cross-section. Upstream ports collect total pressure and separate ports collect static pressure; each set is internally averaged before reaching the external connectors. The resulting differential pressure represents mean duct velocity more reliably than a single-point pickup. Connected to a differential transmitter or controller, the sensor supports continuous volume-flow indication, alarm or closed-loop regulation without an active electronic element in the duct.

Ciri-ciri Utama

Multiple sensing ports average velocity variation across the duct cross-section.

Separate total and static chambers provide a continuous differential pressure signal.

Passive probe construction needs no power or electronics inside the airstream.

External barbed or compression fittings simplify connection to a remote transmitter.

Kebimbangan Produk Pelanggan

Single-point velocity readings often misrepresent total duct airflow when profiles are uneven after elbows, dampers or transitions.

A central pitot point misses high and low velocity regions across the duct.Distributed ports average the profile across multiple locations.
Electronics in the duct are difficult to service and expose wiring to airflow.The passive sensing grid sends only pneumatic signals to an external transmitter.
Tubing connections are inaccessible after ceiling closure.External manifolds place total and static fittings at a serviceable duct location.
Incorrect duct dimensions produce an inaccurate volume-flow value.The controller uses the actual duct area and measured differential to calculate airflow.

Permohonan yang biasa

AHU supply airflow measurementCleanroom main-duct monitoringReturn-air volume trackingExhaust airflow control

Parameter teknikal

Typical construction for a cleanroom duct averaging airflow sensor is listed below.

Bahan Teras6063 anodized aluminum sensing tubes with galvanized steel or stainless mounting frame
Ketebalan Panel25-60 mm sensing-tube depth
Lebar berkesan200-1500 mm duct span
Panjang maksimumUp to 1800 mm sensing-grid length
Keluli Menghadapi Ketebalan1.2-1.6 mm galvanized or stainless mounting frame
Ketumpatan teras2650-2750 kg/m³ for aluminum sensing elements
Kekonduksian Terma150-220 W/(m·K) for aluminum sensing tubes
Kemasan permukaanNatural anodized aluminum tubes with clean zinc-coated or satin stainless frame
Jenis BersatuDuct flange or insertion brackets with separated total-static pressure connectors
PenyesuaianBoleh didapati berdasarkan aplikasi yang dimaksudkan dan persekitaran operasi.

Pilihan yang boleh didapati

Cross-grid or single-span probeAluminum or stainless constructionCircular or rectangular duct fitBarbed or compression fittings