클린룸 장비 및 무균 시설 필수품의 원스톱 공급업체국제 프로젝트 지원
Open mobile navigationClose mobile navigation
클린룸 제어 및 환경 모니터링 시스템 (Cleanroom Control and Environment Monitoring Systems)

공기 흐름 센서

A multi-point averaging sensor that samples total and static pressure across a duct and produces a stable differential signal for air-volume calculation.
  • Multi-Point Duct Averaging
  • Total and Static Pressure
  • Low Permanent Pressure Loss
  • External Tubing Ports
견적 요청 제품 찾아보기

상품 소개

The duct airflow sensor uses perforated aluminum or stainless sensing tubes positioned across the duct cross-section. Upstream ports collect total pressure and separate ports collect static pressure; each set is internally averaged before reaching the external connectors. The resulting differential pressure represents mean duct velocity more reliably than a single-point pickup. Connected to a differential transmitter or controller, the sensor supports continuous volume-flow indication, alarm or closed-loop regulation without an active electronic element in the duct.

주요 기능

Multiple sensing ports average velocity variation across the duct cross-section.

Separate total and static chambers provide a continuous differential pressure signal.

Passive probe construction needs no power or electronics inside the airstream.

External barbed or compression fittings simplify connection to a remote transmitter.

고객 제품 관심사

Single-point velocity readings often misrepresent total duct airflow when profiles are uneven after elbows, dampers or transitions.

A central pitot point misses high and low velocity regions across the duct.Distributed ports average the profile across multiple locations.
Electronics in the duct are difficult to service and expose wiring to airflow.The passive sensing grid sends only pneumatic signals to an external transmitter.
Tubing connections are inaccessible after ceiling closure.External manifolds place total and static fittings at a serviceable duct location.
Incorrect duct dimensions produce an inaccurate volume-flow value.The controller uses the actual duct area and measured differential to calculate airflow.

일반적인 응용 프로그램

AHU supply airflow measurementCleanroom main-duct monitoringReturn-air volume trackingExhaust airflow control

기술 매개변수

Typical construction for a cleanroom duct averaging airflow sensor is listed below.

핵심 재료6063 anodized aluminum sensing tubes with galvanized steel or stainless mounting frame
패널 두께25-60 mm sensing-tube depth
유효 폭200-1500 mm duct span
최대 길이Up to 1800 mm sensing-grid length
강철 면면 두께1.2-1.6 mm galvanized or stainless mounting frame
코어 밀도2650-2750 kg/m³ for aluminum sensing elements
열전도도 (Thermal Conductivity)150-220 W/(m·K) for aluminum sensing tubes
표면 마무리Natural anodized aluminum tubes with clean zinc-coated or satin stainless frame
접합 유형Duct flange or insertion brackets with separated total-static pressure connectors
사용자 정의의도된 응용 프로그램 및 운영 환경에 따라 사용할 수 있습니다.

사용 가능한 옵션

Cross-grid or single-span probeAluminum or stainless constructionCircular or rectangular duct fitBarbed or compression fittings

Planning a Airflow Sensor specification?

치수, 설치 조건, 성능 목표 및 필요한 표면 마감을 보내십시오.

우리 팀과 대화하십시오.
저희에게 이메일 whatsapp WeChat

제품

뉴스

회사 소개

문의하기