クリーンルーム機器と無菌施設の必需品のワンストップサプライヤー国際プロジェクト支援
Open mobile navigationClose mobile navigation
クリーンルーム管理 · 環境モニタリングシステム

A 空気の流れセンサー

A multi-point averaging sensor that samples total and static pressure across a duct and produces a stable differential signal for air-volume calculation.
  • Multi-Point Duct Averaging
  • Total and Static Pressure
  • Low Permanent Pressure Loss
  • External Tubing Ports
見積もりリクエスト 製品案内

商品紹介

The duct airflow sensor uses perforated aluminum or stainless sensing tubes positioned across the duct cross-section. Upstream ports collect total pressure and separate ports collect static pressure; each set is internally averaged before reaching the external connectors. The resulting differential pressure represents mean duct velocity more reliably than a single-point pickup. Connected to a differential transmitter or controller, the sensor supports continuous volume-flow indication, alarm or closed-loop regulation without an active electronic element in the duct.

主要な特徴

Multiple sensing ports average velocity variation across the duct cross-section.

Separate total and static chambers provide a continuous differential pressure signal.

Passive probe construction needs no power or electronics inside the airstream.

External barbed or compression fittings simplify connection to a remote transmitter.

お客様の製品に関する懸念事項

Single-point velocity readings often misrepresent total duct airflow when profiles are uneven after elbows, dampers or transitions.

A central pitot point misses high and low velocity regions across the duct.Distributed ports average the profile across multiple locations.
Electronics in the duct are difficult to service and expose wiring to airflow.The passive sensing grid sends only pneumatic signals to an external transmitter.
Tubing connections are inaccessible after ceiling closure.External manifolds place total and static fittings at a serviceable duct location.
Incorrect duct dimensions produce an inaccurate volume-flow value.The controller uses the actual duct area and measured differential to calculate airflow.

典型的な用途

AHU supply airflow measurementCleanroom main-duct monitoringReturn-air volume trackingExhaust airflow control

技術的なパラメータ

Typical construction for a cleanroom duct averaging airflow sensor is listed below.

コア材料6063 anodized aluminum sensing tubes with galvanized steel or stainless mounting frame
パネルの厚さ25-60 mm sensing-tube depth
有効幅200-1500 mm duct span
最大長さUp to 1800 mm sensing-grid length
鋼鉄の厚さを直面する1.2-1.6 mm galvanized or stainless mounting frame
コア密度2650-2750 kg/m³ for aluminum sensing elements
熱伝導率150-220 W/(m·K) for aluminum sensing tubes
表面仕上げNatural anodized aluminum tubes with clean zinc-coated or satin stainless frame
ジョイントタイプDuct flange or insertion brackets with separated total-static pressure connectors
カスタマイズ意図したアプリケーションと動作環境に基づいて利用できます。

利用可能なオプション

Cross-grid or single-span probeAluminum or stainless constructionCircular or rectangular duct fitBarbed or compression fittings

Planning a Airflow Sensor specification?

寸法、設置条件、性能目標、必要な表面仕上げをお送りください。

チームに相談する
メール送信 WhatsApp WeChat

ホーム

製品

ニュース

会社概要

お問い合わせ