Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Системы контроля за чистыми помещениями и экологического мониторинга

Датчик воздушного потока

A multi-point averaging sensor that samples total and static pressure across a duct and produces a stable differential signal for air-volume calculation.
  • Multi-Point Duct Averaging
  • Total and Static Pressure
  • Low Permanent Pressure Loss
  • External Tubing Ports
Запрос котировки Просмотреть продукты

Введение продукции

The duct airflow sensor uses perforated aluminum or stainless sensing tubes positioned across the duct cross-section. Upstream ports collect total pressure and separate ports collect static pressure; each set is internally averaged before reaching the external connectors. The resulting differential pressure represents mean duct velocity more reliably than a single-point pickup. Connected to a differential transmitter or controller, the sensor supports continuous volume-flow indication, alarm or closed-loop regulation without an active electronic element in the duct.

Основные характеристики

Multiple sensing ports average velocity variation across the duct cross-section.

Separate total and static chambers provide a continuous differential pressure signal.

Passive probe construction needs no power or electronics inside the airstream.

External barbed or compression fittings simplify connection to a remote transmitter.

Обеспокоенность клиентов продуктами

Single-point velocity readings often misrepresent total duct airflow when profiles are uneven after elbows, dampers or transitions.

A central pitot point misses high and low velocity regions across the duct.Distributed ports average the profile across multiple locations.
Electronics in the duct are difficult to service and expose wiring to airflow.The passive sensing grid sends only pneumatic signals to an external transmitter.
Tubing connections are inaccessible after ceiling closure.External manifolds place total and static fittings at a serviceable duct location.
Incorrect duct dimensions produce an inaccurate volume-flow value.The controller uses the actual duct area and measured differential to calculate airflow.

Типичные приложения

AHU supply airflow measurementCleanroom main-duct monitoringReturn-air volume trackingExhaust airflow control

Технические параметры

Typical construction for a cleanroom duct averaging airflow sensor is listed below.

Основной материал6063 anodized aluminum sensing tubes with galvanized steel or stainless mounting frame
Толщина панели25-60 mm sensing-tube depth
эффективная ширина200-1500 mm duct span
Максимальная длинаUp to 1800 mm sensing-grid length
Толщина линий стали1.2-1.6 mm galvanized or stainless mounting frame
Плотность ядра2650-2750 kg/m³ for aluminum sensing elements
Теплопроводимость150-220 W/(m·K) for aluminum sensing tubes
Поверхностная отделкаNatural anodized aluminum tubes with clean zinc-coated or satin stainless frame
Объединенный типDuct flange or insertion brackets with separated total-static pressure connectors
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Cross-grid or single-span probeAluminum or stainless constructionCircular or rectangular duct fitBarbed or compression fittings

Planning a Airflow Sensor specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой
Электронная почта WhatsApp WeChat

Главная

Продукция

Новости

О нас

Контакты