Temiz Oda Ekipmanları ve Aseptik Tesis Temelleri için Tek Duraklı TedarikçinizUluslararası Proje Destekleri
Open mobile navigationClose mobile navigation
Ana Sayfa / Ürünler / Laminar Flow ve Containment Equipment / Class I Biological Safety Cabinet
Laminar Flow ve Containment Equipment

Sınıf I Biyolojik Güvenlik Kabinesi

An open-front ventilated cabinet that draws room air inward and filters the exhaust to protect personnel and the environment, but not the handled product.
  • Inward Face Airflow
  • HEPA-Filtered Exhaust
  • Personnel and Environmental Protection
  • Open-Front Access
Alıntı isteği Browse ürünleri

Ürün tanıtımı

A Class I cabinet uses inward airflow through the front opening to keep aerosols and particles moving away from the operator. The contaminated air passes through an exhaust HEPA filter before discharge to the room or building exhaust system. Because unfiltered room air crosses the work surface, the cabinet does not protect the product from ambient contamination. The sash, inflow monitor and exhaust connection are configured for the intended laboratory use and installation.

Ana Özellikler

Continuous inward airflow forms the primary operator-protection boundary.

The exhaust HEPA stage retains particulate contamination before air discharge.

A sloped viewing sash improves visibility while limiting the working opening.

A removable work tray exposes the lower catch pan for cleaning.

Airflow and sash alarms warn when the designed access condition is disturbed.

Müşteri Ürün Sorunları

The cabinet must protect the operator without being misrepresented as a sterile product-protection device.

Aerosols move toward the operator at an open laboratory bench.Inward face airflow carries them into the filtered cabinet exhaust path.
Users expect the cabinet to keep samples sterile.Clear application guidance states that room air crosses the work surface and product protection is not provided.
A raised sash weakens capture at the opening.A sash-position alarm identifies operation outside the selected access height.
Debris accumulates beneath a fixed work pan.Lift-out work sections expose the stainless lower collection area.

Tipik uygulamalar

Aerosol-generating laboratory procedures not requiring sterile product protectionAnimal bedding disposalSample opening under inward captureEquipment enclosure with filtered exhaust

Teknik parametreler

Typical configurable construction ranges for a Class I biological safety cabinet are listed below.

Temel malzemelerSUS304 work-zone liner with powder-coated steel outer shell and mineral-wool acoustic exhaust enclosure
Panel kalınlığı30-50 mm double-skin cabinet and exhaust sections
Effective Width (Etkili Genişlik)900-1800 mm clear working width
Maksimum uzunlukUp to 2200 mm overall cabinet height
Çelik yüz yüze kalınlığı1.0-1.5 mm SUS304 work-zone liner; 0.8-1.2 mm outer steel
Core Density (Çekirdek Yoğunluğu)80-120 kg / m3 mineral-yün akustik dolgu
Termal İletkenlikAkustik dolgu için 0,035-0,045 W/(m·K)
Yüzey bitirmeBrushed SUS304 work zone with low-sheen white powder-coated exterior
Ortak tipWelded inner liner with gasketed exhaust-filter housing and adjustable sash tracks
Customization (Özelleşme)Kullanılan uygulama ve çalışma ortamına göre kullanılabilir.

Mevcut Seçenekler

Room exhaust or hard-duct connectionManual or motorized sashStainless or coated-steel exteriorService taps and electrical outlets

Planning a Class I Biological Safety Cabinet specification?

Bize boyutlarınızı, montaj koşullarınızı, performans hedeflerinizi ve gerekli yüzey kaplamalarınızı gönderin.