Ihr One-Stop - Lieferant für Reinraumausrüstung und Essentials für aseptische EinrichtungenInternationale Projektunterstützung
Open mobile navigationClose mobile navigation
Startseite / Produkte / Laminar Flow und Containment Equipment / Class I Biological Safety Cabinet
Laminar Flow und Containment Equipment

Klasse I Biologische Sicherheit Cabinet

An open-front ventilated cabinet that draws room air inward and filters the exhaust to protect personnel and the environment, but not the handled product.
  • Inward Face Airflow
  • HEPA-Filtered Exhaust
  • Personnel and Environmental Protection
  • Open-Front Access

Produkteinführung

A Class I cabinet uses inward airflow through the front opening to keep aerosols and particles moving away from the operator. The contaminated air passes through an exhaust HEPA filter before discharge to the room or building exhaust system. Because unfiltered room air crosses the work surface, the cabinet does not protect the product from ambient contamination. The sash, inflow monitor and exhaust connection are configured for the intended laboratory use and installation.

Key Features

Continuous inward airflow forms the primary operator-protection boundary.

The exhaust HEPA stage retains particulate contamination before air discharge.

A sloped viewing sash improves visibility while limiting the working opening.

A removable work tray exposes the lower catch pan for cleaning.

Airflow and sash alarms warn when the designed access condition is disturbed.

Kunden Produktbedenken

The cabinet must protect the operator without being misrepresented as a sterile product-protection device.

Aerosols move toward the operator at an open laboratory bench.Inward face airflow carries them into the filtered cabinet exhaust path.
Users expect the cabinet to keep samples sterile.Clear application guidance states that room air crosses the work surface and product protection is not provided.
A raised sash weakens capture at the opening.A sash-position alarm identifies operation outside the selected access height.
Debris accumulates beneath a fixed work pan.Lift-out work sections expose the stainless lower collection area.

Typische Anwendungen

Aerosol-generating laboratory procedures not requiring sterile product protectionAnimal bedding disposalSample opening under inward captureEquipment enclosure with filtered exhaust

Technische Parameter

Typical configurable construction ranges for a Class I biological safety cabinet are listed below.

Core MaterialSUS304 work-zone liner with powder-coated steel outer shell and mineral-wool acoustic exhaust enclosure
Panel Dicke30-50 mm double-skin cabinet and exhaust sections
Effektive Breite900 - 1800 mm klare Arbeitsbreite
Maximale LängeBis zu 2200 mm Gesamtschrankhöhe
Stahl facing Dicke1.0-1.5 mm SUS304 work-zone liner; 0.8-1.2 mm outer steel
Kerndichte80 - 120 kg / m3 Mineralwolle Akustikfüllung
Thermische Leitfähigkeit0,035 - 0,045 W / (m · K) für die Akustikfüllung
Oberfläche FinishBrushed SUS304 work zone with low-sheen white powder-coated exterior
Gemeinsamer TypWelded inner liner with gasketed exhaust-filter housing and adjustable sash tracks
CustomisierungVerfügbar je nach beabsichtigter Anwendung und Betriebsumgebung.

Verfügbare Optionen

Room exhaust or hard-duct connectionManual or motorized sashStainless or coated-steel exteriorService taps and electrical outlets

Planning a Class I Biological Safety Cabinet specification?

Senden Sie uns Ihre Abmessungen, Installationsbedingungen, Leistungsziele und gewünschte Oberflächenveredelung.

Sprechen Sie mit unserem Team
E-Mail uns WhatsApp WeChat

Startseite

Produkte

Neuigkeiten

Über uns

Kontakt