Ваш универсальный поставщик оборудования для чистых помещений и асептических средствПоддержка международных проектов
Open mobile navigationClose mobile navigation
Оборудование для ламинарного потока и ограничения

Класс I кабинет биологической безопасности

An open-front ventilated cabinet that draws room air inward and filters the exhaust to protect personnel and the environment, but not the handled product.
  • Inward Face Airflow
  • HEPA-Filtered Exhaust
  • Personnel and Environmental Protection
  • Open-Front Access
Запрос котировки Просмотреть продукты

Введение продукции

A Class I cabinet uses inward airflow through the front opening to keep aerosols and particles moving away from the operator. The contaminated air passes through an exhaust HEPA filter before discharge to the room or building exhaust system. Because unfiltered room air crosses the work surface, the cabinet does not protect the product from ambient contamination. The sash, inflow monitor and exhaust connection are configured for the intended laboratory use and installation.

Основные характеристики

Continuous inward airflow forms the primary operator-protection boundary.

The exhaust HEPA stage retains particulate contamination before air discharge.

A sloped viewing sash improves visibility while limiting the working opening.

A removable work tray exposes the lower catch pan for cleaning.

Airflow and sash alarms warn when the designed access condition is disturbed.

Обеспокоенность клиентов продуктами

The cabinet must protect the operator without being misrepresented as a sterile product-protection device.

Aerosols move toward the operator at an open laboratory bench.Inward face airflow carries them into the filtered cabinet exhaust path.
Users expect the cabinet to keep samples sterile.Clear application guidance states that room air crosses the work surface and product protection is not provided.
A raised sash weakens capture at the opening.A sash-position alarm identifies operation outside the selected access height.
Debris accumulates beneath a fixed work pan.Lift-out work sections expose the stainless lower collection area.

Типичные приложения

Aerosol-generating laboratory procedures not requiring sterile product protectionAnimal bedding disposalSample opening under inward captureEquipment enclosure with filtered exhaust

Технические параметры

Typical configurable construction ranges for a Class I biological safety cabinet are listed below.

Основной материалSUS304 work-zone liner with powder-coated steel outer shell and mineral-wool acoustic exhaust enclosure
Толщина панели30-50 mm double-skin cabinet and exhaust sections
эффективная ширина900-1800 mm clear working width
Максимальная длинаUp to 2200 mm overall cabinet height
Толщина линий стали1.0-1.5 mm SUS304 work-zone liner; 0.8-1.2 mm outer steel
Плотность ядра80-120 kg/m³ mineral-wool acoustic infill
Теплопроводимость0.035-0.045 W/(m·K) for the acoustic infill
Поверхностная отделкаBrushed SUS304 work zone with low-sheen white powder-coated exterior
Объединенный типWelded inner liner with gasketed exhaust-filter housing and adjustable sash tracks
CustomizationДоступно в зависимости от предполагаемого применения и операционной среды.

Доступные варианты

Room exhaust or hard-duct connectionManual or motorized sashStainless or coated-steel exteriorService taps and electrical outlets

Planning a Class I Biological Safety Cabinet specification?

Отправьте нам ваши габариты, условия монтажа, целевые показатели производительности и требуемую отделку поверхности.

Поговорите с нашей командой