Su proveedor de ventanilla única para equipos de sala limpia y elementos esenciales para instalaciones asépticasApoyo a proyectos internacionales
Open mobile navigationClose mobile navigation
Inicio / Productos / Equipos de flujo laminar y contención / Class I Biological Safety Cabinet
Equipos de flujo laminar y contención

Gabinete de Seguridad Biológica Clase I

An open-front ventilated cabinet that draws room air inward and filters the exhaust to protect personnel and the environment, but not the handled product.
  • Inward Face Airflow
  • HEPA-Filtered Exhaust
  • Personnel and Environmental Protection
  • Open-Front Access
Solicite un presupuesto. Browse productos

Introducción del producto

A Class I cabinet uses inward airflow through the front opening to keep aerosols and particles moving away from the operator. The contaminated air passes through an exhaust HEPA filter before discharge to the room or building exhaust system. Because unfiltered room air crosses the work surface, the cabinet does not protect the product from ambient contamination. The sash, inflow monitor and exhaust connection are configured for the intended laboratory use and installation.

Características clave

Continuous inward airflow forms the primary operator-protection boundary.

The exhaust HEPA stage retains particulate contamination before air discharge.

A sloped viewing sash improves visibility while limiting the working opening.

A removable work tray exposes the lower catch pan for cleaning.

Airflow and sash alarms warn when the designed access condition is disturbed.

Preocupaciones del producto del cliente

The cabinet must protect the operator without being misrepresented as a sterile product-protection device.

Aerosols move toward the operator at an open laboratory bench.Inward face airflow carries them into the filtered cabinet exhaust path.
Users expect the cabinet to keep samples sterile.Clear application guidance states that room air crosses the work surface and product protection is not provided.
A raised sash weakens capture at the opening.A sash-position alarm identifies operation outside the selected access height.
Debris accumulates beneath a fixed work pan.Lift-out work sections expose the stainless lower collection area.

Aplicaciones típicas

Aerosol-generating laboratory procedures not requiring sterile product protectionAnimal bedding disposalSample opening under inward captureEquipment enclosure with filtered exhaust

Parámetros técnicos

Typical configurable construction ranges for a Class I biological safety cabinet are listed below.

Materiales CoreSUS304 work-zone liner with powder-coated steel outer shell and mineral-wool acoustic exhaust enclosure
Panel de espesor30-50 mm double-skin cabinet and exhaust sections
Ancho efectivo900 - 1800 mm Ancho de trabajo claro
Longitud máximaHasta 2200 mm de altura total del gabinete
Acero frente a espesor1.0-1.5 mm SUS304 work-zone liner; 0.8-1.2 mm outer steel
Densidad Core80 - 120 kg / m3 relleno acústico de lana mineral por
Conductividad térmica0,035 - 0,045 W / (m · K) para el relleno acústico
Superficie acabadaBrushed SUS304 work zone with low-sheen white powder-coated exterior
Tipo conjuntoWelded inner liner with gasketed exhaust-filter housing and adjustable sash tracks
CustomizationDisponible según la aplicación prevista y el entorno operativo.

Opciones disponibles

Room exhaust or hard-duct connectionManual or motorized sashStainless or coated-steel exteriorService taps and electrical outlets

Planning a Class I Biological Safety Cabinet specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.