Votre fournisseur à guichet unique pour les équipements de salle blanche et les essentiels des installations aseptiquesSoutien international aux projets
Open mobile navigationClose mobile navigation
Équipement d'écoulement et de confinement laminaires

Cabinet de sécurité biologique de classe I par

An open-front ventilated cabinet that draws room air inward and filters the exhaust to protect personnel and the environment, but not the handled product.
  • Inward Face Airflow
  • HEPA-Filtered Exhaust
  • Personnel and Environmental Protection
  • Open-Front Access
Demander un devis. Browse les produits

Introduction de produit

A Class I cabinet uses inward airflow through the front opening to keep aerosols and particles moving away from the operator. The contaminated air passes through an exhaust HEPA filter before discharge to the room or building exhaust system. Because unfiltered room air crosses the work surface, the cabinet does not protect the product from ambient contamination. The sash, inflow monitor and exhaust connection are configured for the intended laboratory use and installation.

Key Features

Continuous inward airflow forms the primary operator-protection boundary.

The exhaust HEPA stage retains particulate contamination before air discharge.

A sloped viewing sash improves visibility while limiting the working opening.

A removable work tray exposes the lower catch pan for cleaning.

Airflow and sash alarms warn when the designed access condition is disturbed.

Préoccupations du client produit

The cabinet must protect the operator without being misrepresented as a sterile product-protection device.

Aerosols move toward the operator at an open laboratory bench.Inward face airflow carries them into the filtered cabinet exhaust path.
Users expect the cabinet to keep samples sterile.Clear application guidance states that room air crosses the work surface and product protection is not provided.
A raised sash weakens capture at the opening.A sash-position alarm identifies operation outside the selected access height.
Debris accumulates beneath a fixed work pan.Lift-out work sections expose the stainless lower collection area.

Les applications typiques

Aerosol-generating laboratory procedures not requiring sterile product protectionAnimal bedding disposalSample opening under inward captureEquipment enclosure with filtered exhaust

Paramètres techniques

Typical configurable construction ranges for a Class I biological safety cabinet are listed below.

Matériaux de baseSUS304 work-zone liner with powder-coated steel outer shell and mineral-wool acoustic exhaust enclosure
Panneau épaisseur30-50 mm double-skin cabinet and exhaust sections
Largeur effective900 - 1800 mm Largeur de travail claire
Longueur maximaleJusqu'à 2200 mm de hauteur totale du cabinet
Acier face épaisseur1.0-1.5 mm SUS304 work-zone liner; 0.8-1.2 mm outer steel
Densité Core80 - 120 kg / m3 remplissage acoustique en laine minérale par
Conductivité thermique0,035 - 0,045 W / (m · K) pour le remplissage acoustique
surface finieBrushed SUS304 work zone with low-sheen white powder-coated exterior
Type jointWelded inner liner with gasketed exhaust-filter housing and adjustable sash tracks
CustomisationDisponible en fonction de l'application prévue et de l'environnement d'exploitation.

Options disponibles

Room exhaust or hard-duct connectionManual or motorized sashStainless or coated-steel exteriorService taps and electrical outlets

Planning a Class I Biological Safety Cabinet specification?

Envoyez-nous vos dimensions, conditions d'installation, objectifs de performance et finition de surface requise.

Parlez à notre équipe