Pemasok One-Stop Anda untuk Peralatan Cleanroom dan Fasilitas Aseptik EsensialDukungan proyek internasional
Open mobile navigationClose mobile navigation
Beranda / Produk / Aliran Laminar dan Peralatan Penahanan / Class I Biological Safety Cabinet
Aliran Laminar dan Peralatan Penahanan

Kabinet Keamanan Biologi Kelas I

An open-front ventilated cabinet that draws room air inward and filters the exhaust to protect personnel and the environment, but not the handled product.
  • Inward Face Airflow
  • HEPA-Filtered Exhaust
  • Personnel and Environmental Protection
  • Open-Front Access
Permintaan untuk kutipan Browse Produk

Perkenalan produk

A Class I cabinet uses inward airflow through the front opening to keep aerosols and particles moving away from the operator. The contaminated air passes through an exhaust HEPA filter before discharge to the room or building exhaust system. Because unfiltered room air crosses the work surface, the cabinet does not protect the product from ambient contamination. The sash, inflow monitor and exhaust connection are configured for the intended laboratory use and installation.

Fitur utama:

Continuous inward airflow forms the primary operator-protection boundary.

The exhaust HEPA stage retains particulate contamination before air discharge.

A sloped viewing sash improves visibility while limiting the working opening.

A removable work tray exposes the lower catch pan for cleaning.

Airflow and sash alarms warn when the designed access condition is disturbed.

Kekhawatiran produk pelanggan

The cabinet must protect the operator without being misrepresented as a sterile product-protection device.

Aerosols move toward the operator at an open laboratory bench.Inward face airflow carries them into the filtered cabinet exhaust path.
Users expect the cabinet to keep samples sterile.Clear application guidance states that room air crosses the work surface and product protection is not provided.
A raised sash weakens capture at the opening.A sash-position alarm identifies operation outside the selected access height.
Debris accumulates beneath a fixed work pan.Lift-out work sections expose the stainless lower collection area.

Aplikasi yang Tipis

Aerosol-generating laboratory procedures not requiring sterile product protectionAnimal bedding disposalSample opening under inward captureEquipment enclosure with filtered exhaust

Parameter teknis

Typical configurable construction ranges for a Class I biological safety cabinet are listed below.

Bahan intiSUS304 work-zone liner with powder-coated steel outer shell and mineral-wool acoustic exhaust enclosure
Ketebalan Panel (Panel Thickness)30-50 mm double-skin cabinet and exhaust sections
Efektif lebar900 - 1800 mm lebar kerja yang jelas
Panjang maksimumHingga 2200 mm ketinggian kabinet keseluruhan
Baja menghadap ketebalan1.0-1.5 mm SUS304 work-zone liner; 0.8-1.2 mm outer steel
Kepadatan inti (core density)80 - 120 kg / m3 mineral-wol akustik infill
Konduktivitas Termal (Thermal Conductivity)0,035 - 0,045 W / (m · K) untuk infill akustik
Permukaan selesaiBrushed SUS304 work zone with low-sheen white powder-coated exterior
Jenis BersamaWelded inner liner with gasketed exhaust-filter housing and adjustable sash tracks
Customization (Kustomisasi)Tersedia berdasarkan aplikasi yang dimaksudkan dan lingkungan operasi.

Pilihan yang tersedia

Room exhaust or hard-duct connectionManual or motorized sashStainless or coated-steel exteriorService taps and electrical outlets

Planning a Class I Biological Safety Cabinet specification?

Kirimkan kami dimensi Anda, kondisi instalasi, target kinerja dan permukaan akhir yang diperlukan.

Bicaralah dengan tim kami
Email Kami WhatsApp WhatsApp WhatsApp WhatsApp WeChat adalah

Beranda

Produk

Berita

Tentang Kami

Hubungi Kami