Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Portas de sala limpa, janelas e sistemas de bloqueio

Sistema de bloqueio de sala limpa de duas portas

A complete interlock package for a two-door personnel or material airlock, allowing only the permitted door to release while the opposite opening remains secured.
  • Dedicated Two-Door Logic
  • Two Lock and Contact Channels
  • Request/Wait Indication
  • Emergency Release Input
Solicite um orçamento. Browse produtos

Introdução do produto

The two-door system packages a compact controller with two door-position sensors, two electric-lock interfaces and paired request/status stations. In normal operation, opening one door inhibits release of the opposite door until the first door closes and any selected purge delay expires. The limited door count makes commissioning straightforward and suits common entry vestibules, gowning airlocks and pass-through rooms where the interlock relationship is one-to-one.

Características-chave

Two dedicated channels provide direct door-to-door inhibition without unnecessary network complexity.

Request and wait indicators show occupants when the opposite door is in use.

A resettable delay can hold both doors closed while filtered air restores the vestibule condition.

Emergency release and optional fire-alarm input override normal sequencing according to the selected safety design.

Preocupações do produto do cliente

A simple two-door airlock still requires reliable state feedback, clear occupant indication and a defined response to emergency release or power loss.

Both vestibule doors are opened together during busy shift changes.The active door channel inhibits the opposite lock release until closed feedback is restored.
Users repeatedly pull a locked door because they cannot see the airlock status.Paired request stations provide distinct available and wait indications at each entrance.
The second door opens before the airlock has recovered after the first cycle.An adjustable inter-door delay holds release until the selected purge interval has elapsed.

Aplicações típicas

Two-door personnel airlocksGowning-room vestibulesMaterial transfer roomsClean laboratory entrance lobbies

Parâmetros técnicos

Typical physical and electrical ranges for a two-door cleanroom interlock kit are listed below.

Material principalTwo-channel controller, regulated power supply, relays, door contacts and request/indicator stations
Painel de espessura80–130 mm controller enclosure depth; 10–25 mm operator-station depth
Largura efetiva200–280 mm controller enclosure width
Comprimento máximo320 mm controller enclosure height
Aço enfrentando espessura1.0–1.5 mm steel enclosure; stainless operator plates typically 1.2–2.0 mm
Densidade CoreApproximately 1800–1920 kg/m³ for the two-channel glass-reinforced PCB laminate
Condutividade térmicaApproximately 0.4–0.7 W/(m·K) for the controller PCB laminate
Superfície acabadoPowder-coated controller cabinet with brushed stainless or flush polymer request stations
Tipo conjuntoTwo independent door-contact and lock channels with hardwired request, alarm and emergency-release inputs
CustomizaçãoDisponível com base na aplicação pretendida e ambiente operacional

Opções disponíveis

Touch, touchless or mechanical request stationsMagnetic locks or electric strikesPurge timer and door-held alarmNormally locked or normally unlocked sequence