A complete interlock package for a two-door personnel or material airlock, allowing only the permitted door to release while the opposite opening remains secured.
  • Dedicated Two-Door Logic
  • Two Lock and Contact Channels
  • Request/Wait Indication
  • Emergency Release Input
견적 요청 제품 찾아보기

상품 소개

The two-door system packages a compact controller with two door-position sensors, two electric-lock interfaces and paired request/status stations. In normal operation, opening one door inhibits release of the opposite door until the first door closes and any selected purge delay expires. The limited door count makes commissioning straightforward and suits common entry vestibules, gowning airlocks and pass-through rooms where the interlock relationship is one-to-one.

주요 기능

Two dedicated channels provide direct door-to-door inhibition without unnecessary network complexity.

Request and wait indicators show occupants when the opposite door is in use.

A resettable delay can hold both doors closed while filtered air restores the vestibule condition.

Emergency release and optional fire-alarm input override normal sequencing according to the selected safety design.

고객 제품 관심사

A simple two-door airlock still requires reliable state feedback, clear occupant indication and a defined response to emergency release or power loss.

Both vestibule doors are opened together during busy shift changes.The active door channel inhibits the opposite lock release until closed feedback is restored.
Users repeatedly pull a locked door because they cannot see the airlock status.Paired request stations provide distinct available and wait indications at each entrance.
The second door opens before the airlock has recovered after the first cycle.An adjustable inter-door delay holds release until the selected purge interval has elapsed.

일반적인 응용 프로그램

Two-door personnel airlocksGowning-room vestibulesMaterial transfer roomsClean laboratory entrance lobbies

기술 매개변수

Typical physical and electrical ranges for a two-door cleanroom interlock kit are listed below.

핵심 재료Two-channel controller, regulated power supply, relays, door contacts and request/indicator stations
패널 두께80–130 mm controller enclosure depth; 10–25 mm operator-station depth
유효 폭200–280 mm controller enclosure width
최대 길이320 mm controller enclosure height
강철 면면 두께1.0–1.5 mm steel enclosure; stainless operator plates typically 1.2–2.0 mm
코어 밀도Approximately 1800–1920 kg/m³ for the two-channel glass-reinforced PCB laminate
열전도도 (Thermal Conductivity)Approximately 0.4–0.7 W/(m·K) for the controller PCB laminate
표면 마무리Powder-coated controller cabinet with brushed stainless or flush polymer request stations
접합 유형Two independent door-contact and lock channels with hardwired request, alarm and emergency-release inputs
사용자 정의사용 대상 어플리케이션 및 운영 환경에 따라 사용 가능