Sistema de bloqueo de sala limpia de dos puertas

A complete interlock package for a two-door personnel or material airlock, allowing only the permitted door to release while the opposite opening remains secured.
  • Dedicated Two-Door Logic
  • Two Lock and Contact Channels
  • Request/Wait Indication
  • Emergency Release Input
Solicite un presupuesto. Browse productos

Introducción del producto

The two-door system packages a compact controller with two door-position sensors, two electric-lock interfaces and paired request/status stations. In normal operation, opening one door inhibits release of the opposite door until the first door closes and any selected purge delay expires. The limited door count makes commissioning straightforward and suits common entry vestibules, gowning airlocks and pass-through rooms where the interlock relationship is one-to-one.

Características clave

Two dedicated channels provide direct door-to-door inhibition without unnecessary network complexity.

Request and wait indicators show occupants when the opposite door is in use.

A resettable delay can hold both doors closed while filtered air restores the vestibule condition.

Emergency release and optional fire-alarm input override normal sequencing according to the selected safety design.

Preocupaciones del producto del cliente

A simple two-door airlock still requires reliable state feedback, clear occupant indication and a defined response to emergency release or power loss.

Both vestibule doors are opened together during busy shift changes.The active door channel inhibits the opposite lock release until closed feedback is restored.
Users repeatedly pull a locked door because they cannot see the airlock status.Paired request stations provide distinct available and wait indications at each entrance.
The second door opens before the airlock has recovered after the first cycle.An adjustable inter-door delay holds release until the selected purge interval has elapsed.

Aplicaciones típicas

Two-door personnel airlocksGowning-room vestibulesMaterial transfer roomsClean laboratory entrance lobbies

Parámetros técnicos

Typical physical and electrical ranges for a two-door cleanroom interlock kit are listed below.

Materiales CoreTwo-channel controller, regulated power supply, relays, door contacts and request/indicator stations
Panel de espesor80–130 mm controller enclosure depth; 10–25 mm operator-station depth
Ancho efectivo200–280 mm controller enclosure width
Longitud máxima320 mm controller enclosure height
Acero frente a espesor1.0–1.5 mm steel enclosure; stainless operator plates typically 1.2–2.0 mm
Densidad CoreApproximately 1800–1920 kg/m³ for the two-channel glass-reinforced PCB laminate
Conductividad térmicaApproximately 0.4–0.7 W/(m·K) for the controller PCB laminate
Superficie acabadaPowder-coated controller cabinet with brushed stainless or flush polymer request stations
Tipo conjuntoTwo independent door-contact and lock channels with hardwired request, alarm and emergency-release inputs
CustomizationDisponible según la aplicación prevista y el entorno operativo

Opciones disponibles

Touch, touchless or mechanical request stationsMagnetic locks or electric strikesPurge timer and door-held alarmNormally locked or normally unlocked sequence

Planning a Two-Door Cleanroom Interlock System specification?

Envíenos sus dimensiones, condiciones de instalación, objetivos de rendimiento y acabado superficial requerido.