Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Controle de sala limpa e sistemas de monitoramento ambiental

Z Transmissor de temperatura e umidade

A combined wall or duct transmitter that delivers matched temperature and relative-humidity signals from one serviceable sensing assembly.
  • Combined T and RH Measurement
  • Matched Dual Outputs
  • Replaceable Probe Filter
  • Local Display Option
Solicite um orçamento. Browse produtos

Introdução do produto

The temperature and humidity transmitter places a stable temperature element and capacitive humidity sensor in the same aspirated probe so both variables represent the same air sample. Internal electronics compensate and linearize the measurements, then provide separate analog signals or a digital network value set. A replaceable filter protects the probe, while an optional display shows temperature, relative humidity and derived dew point locally. Wall, duct and remote-probe configurations address different cleanroom and AHU measurement locations.

Características-chave

Co-located temperature and humidity elements measure the same local air sample.

Separate calibrated outputs simplify connection to environmental monitoring and HVAC controls.

Replaceable probe filters protect the sensing assembly without replacing the transmitter body.

Optional display presents temperature, RH and derived dew point at the installation location.

Preocupações do produto do cliente

Temperature and humidity values become difficult to interpret when they come from different locations, response times or sensor housings.

Separate sensors report conditions from slightly different air zones.A combined probe measures both variables from one shared air sample.
Humidity drift cannot be distinguished from temperature-driven RH change.Synchronized temperature and RH trends reveal whether moisture content or temperature caused the shift.
Probe contamination requires replacement of the entire transmitter.A serviceable filter and replaceable probe option reduce maintenance scope.
Commissioning staff cannot verify the local reading without a laptop.An optional display provides immediate temperature, humidity and dew-point values.

Aplicações típicas

Cleanroom environmental monitoringAHU supply and return ductsHumidity-controlled storage suitesLaboratory HVAC control

Parâmetros técnicos

Typical construction for a combined cleanroom temperature and humidity transmitter is shown below.

Material principalPlatinum temperature element and capacitive polymer RH sensor in polycarbonate housing with optional stainless probe
Painel de espessura35-60 mm transmitter depth
Largura efetiva100-150 mm wall housing width
Comprimento máximoRemote or duct probes up to 400 mm
Aço enfrentando espessura0-0.8 mm; optional 304 stainless probe tube
Densidade Core1180-1220 kg/m³ for polycarbonate housing components
Condutividade térmica0.19-0.22 W/(m·K) for polycarbonate enclosure material
Superfície acabadoSmooth white housing with black display window and satin stainless probe option
Tipo conjuntoWall base or duct flange with removable filtered probe and pluggable output terminals
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Wall, duct or remote probeDual analog outputsModbus or BACnet communicationLocal dew-point display

Planning a Temperature and Humidity Transmitter specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat

Início

Produtos

Notícias

Sobre nós

Contato