Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Início / Produtos / Portas de sala limpa, janelas e sistemas de bloqueio / Radiation-Shielding Lead Glass Cleanroom Window
Portas de sala limpa, janelas e sistemas de bloqueio

Janela de sala limpa de vidro de chumbo de blindagem de radiação

A radiation-shielding observation window that combines transparent lead-barium glass with lead-lined frame returns to maintain visual access across an X-ray barrier.
  • Lead-Barium Shielding Glass
  • Continuous Shielded Frame
  • Clear Operator Sightline
  • Flush Cleanroom Finish
Solicite um orçamento. Browse produtos

Introdução do produto

This window uses high-density lead-barium glass to provide transparent shielding between a cleanroom or controlled laboratory and an X-ray source. The glass overlaps lead-lined frame returns so the shield does not stop at the visible edge, and the clean side is finished with sealed stainless-steel or powder-coated trim. Glass thickness and corresponding lead equivalence are selected from the operating tube voltage and the room shielding design; the product page does not assign a universal rating to every configuration.

Características-chave

Lead-barium glass maintains direct observation while attenuating diagnostic and industrial X-ray energy.

Overlapping lead-lined reveals continue shielding around the perimeter rather than leaving an edge gap.

Ground and chamfered glass edges reduce handling damage during installation of the dense pane.

A flush sealed room face separates the specialist glass edge and shielding liner from routine cleaning.

Preocupações do produto do cliente

The transparent shield must match the surrounding barrier and preserve continuous overlap at the frame while supporting a significantly heavier pane than ordinary glass.

Radiation can bypass the glazing through an unshielded perimeter reveal.Lead-lined frame returns overlap the lead-glass edge and connect with the adjoining wall shielding.
High-density lead glass is heavy and vulnerable to edge damage during handling.A reinforced frame, full setting blocks and finished safety chamfers distribute the pane load.
Specifying lead equivalence without reference to tube voltage can misstate protection.Glass thickness and shielding value are selected from the required operating voltage and barrier schedule.

Aplicações típicas

X-ray inspection cleanroomsMedical imaging support roomsRadiopharmaceutical laboratoriesNon-destructive testing observation stations

Parâmetros técnicos

Representative Corning Med-X-type glass and cleanroom-frame ranges are shown below; the shielding schedule determines the final glass thickness.

Material principalHigh-lead and barium radiation-shielding glass with lead-lined perimeter frame
Painel de espessura4–20 mm lead glass; typically 75–150 mm overall frame depth
Largura efetiva300–1400 mm clear viewing width
Comprimento máximo2800 mm glass plate length where weight and shielding design permit
Aço enfrentando espessura1.2–2.0 mm stainless-steel liner over project-selected lead sheet
Densidade CoreApproximately 4800 kg/m³ for lead-barium shielding glass
Condutividade térmicaApproximately 0.55–0.75 W/(m·K) for dense lead glass
Superfície acabadoOptically polished clear lead glass with brushed stainless or powder-coated flush trim
Tipo conjuntoFour-side supported glazing with continuous lead overlap, resilient setting blocks and sealed cleanroom perimeter
CustomizaçãoDisponível com base na aplicação pretendida e ambiente operacional

Opções disponíveis

Multiple glass thickness and lead-equivalence rangesLaminated safety constructionSealed double-glazed unit304 or 316 stainless-steel finish

Planning a Radiation-Shielding Lead Glass Cleanroom Window specification?

Envie-nos as suas dimensões, condições de instalação, metas de desempenho e acabamento de superfície necessário.

Fale com a nossa equipe
Email-nos O WhatsApp WeChat