Seu fornecedor único para equipamentos de sala limpa e instalações assépticas essenciaisApoio Internacional a Projetos
Open mobile navigationClose mobile navigation
Iluminação de sala limpa e equipamentos elétricos

Transformador de isolamento

A dry-type transformer that provides galvanic separation, voltage adaptation and optional electrostatic shielding for sensitive cleanroom loads.
  • Galvanically Isolated Windings
  • Low-Noise Laminated Core
  • Electrostatic Shield Option
  • Enclosed Finger-Safe Terminals
Solicite um orçamento. Browse produtos

Introdução do produto

The isolation transformer uses separate primary and secondary windings on a laminated magnetic core. Encapsulated or varnish-impregnated coils resist moisture and vibration, and an optional copper electrostatic shield is bonded to earth between windings to attenuate common-mode noise. The assembly is housed in a non-ventilated or guarded enclosure with clearly separated input and output terminals.

Características-chave

Physically separate windings prevent a direct conductive path between input and output.

Encapsulated coils support consistent insulation and lower audible vibration.

An interwinding shield diverts coupled high-frequency noise to protective earth.

Finger-safe terminal blocks organize primary taps and secondary connections.

Rubber isolation mounts reduce mechanical hum transmitted to the floor or wall.

Preocupações do produto do cliente

Sensitive equipment can be affected by ground noise, voltage mismatch and transformer hum even when the nominal supply remains available.

Common-mode electrical noise enters instrument reference circuits.Galvanic separation and an optional grounded shield reduce capacitive noise transfer.
A transformer enclosure transmits audible hum into a quiet laboratory.A welded core, coil impregnation and resilient mounting pads limit vibration.
Exposed terminal studs create accidental-contact risk.A guarded wiring compartment uses labeled finger-safe connectors.
Dust enters an open ventilated enclosure near a clean process.An encapsulated non-ventilated configuration closes the core and coil from room air.

Aplicações típicas

Sensitive analytical instrumentsCleanroom control powerMedical-device test benchesNoise-sensitive monitoring systems

Parâmetros técnicos

Typical configurable construction ranges for an isolation transformer are listed below.

Material principalGrain-oriented silicon-steel core with separate copper windings, insulation system and optional copper electrostatic shield
Painel de espessura200-650 mm enclosed transformer depth
Largura efetiva250-900 mm cabinet width
Comprimento máximoUp to 1200 mm overall enclosure height
Aço enfrentando espessura1.0-2.0 mm powder-coated steel or stainless enclosure
Densidade CoreApproximately 7600-7700 kg/m³ for laminated electrical steel core material
Condutividade térmica20-30 W/(m·K) for laminated silicon steel across the core assembly
Superfície acabadoLight-grey or white powder-coated enclosure with copper earth and terminal markings
Tipo conjuntoBolted or welded core-and-coil assembly on resilient mounts with segregated terminal compartment
CustomizaçãoDisponível com base na aplicação pretendida e no ambiente operacional.

Opções disponíveis

Single- or three-phase designEncapsulated or ventilated dry typeElectrostatic shieldInput and output voltage tap selection